Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Validation of a novel method for continuous saline tonometry in a procine model.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Visa övriga samt affilieringar
2001 (Engelska)Ingår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 22, nr 3, s. 453-460Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Only intermittent and semi-continuous tonometric measurement of gastric and intestinal pHi is possible with the equipment available today. Earlier we developed a system for continuous saline tonometry and tested it in vitro. To assess the in vivo reliability of this method for continuous gastrointestinal saline tonometry, a standard tonometer for measurement of intestinal pCO2 and corresponding pHi was modified to allow continuous perfusion of physiological saline in a closed system and tested in a porcine model. In 11 anaesthetized and haemodynamically stable pigs, two continuous tonometry balloons were inserted into the distal small bowel, and a standard tonometry balloon was used as reference. To test long-term function of the continuous tonometers the research protocol lasted for eight hours. The two continuous saline tonometers performed well, and after an equilibration time of three hours the mean pHi values were stable between 7.35 and 7.43 and between 7.32 and 7.39 respectively. The standard tonometer measured stable pHi values. These preliminary studies indicate that continuous saline tonometry performs well over eight hours with a small bias and a good precision.

Ort, förlag, år, upplaga, sidor
2001. Vol. 22, nr 3, s. 453-460
Nyckelord [en]
gastrointestinal tonometry, continuous, porcine model
Identifikatorer
URN: urn:nbn:se:umu:diva-4410DOI: 10.1088/0967-3334/22/3/304PubMedID: 11556666Scopus ID: 2-s2.0-0034873218OAI: oai:DiVA.org:umu-4410DiVA, id: diva2:143503
Tillgänglig från: 2005-02-24 Skapad: 2005-02-24 Senast uppdaterad: 2023-03-23Bibliografiskt granskad
Ingår i avhandling
1. Exploring Intestinal Ischemia: An experimental study
Öppna denna publikation i ny flik eller fönster >>Exploring Intestinal Ischemia: An experimental study
2005 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Background and aims: Unrecognized intestinal mucosal ischemia in severely ill patients may trigger development of multiple organ failure. Such ischemia can be evaluated by intraluminal tonometry reflecting mucosal PCO2 and intramucosal pH (pHi). The aims were to develop an apparatus for continuous saline tonometry (CST), to analyse circulatory control mechanisms during intestinal hypoperfusion and to evaluate the effect of dopexamine on intestinal circulation.

Methods: A modified standard tonometry catheter was integrated in a closed system with circulating saline. By measuring saline PCO2 in a measurement unit pHi could be calculated. This novel system was tested in vitro and in vivo. In a porcine study, CST was evaluated against standard saline tonometry, tissue oxygenation (PO2 TISSUE), jejunal mucosal perfusion (laser doppler flowmetry; LDF) and mesenteric net lactate flux during graded reductions of superior mesenteric arterial pressure (PSMA). Local control mechanisms for maintenance of intestinal oxygenation were analysed. Effects of dopexamine on the intestinal vascular bed were explored. Mucosal lactate production was assessed by microdialysis.

Results: CST measured accurate PCO2 values and changes in pHi during restricted intestinal circulation and at reperfusion. Local control mechanisms were insufficient at a PSMA of 30 mmHg, pHi was reduced to 7.10 and intestinal net lactate production was demonstrated. Absence of anaerobic intestinal metabolism was verified at PSMA ≥ 50 mmHg, pHi ≥ 7.22 and a PCO2 gap ≤ 15.8 mmHg. Dopexamine induced negative regional metabolic effects at the lowest PSMA, as expressed by decreased PO2 TISSUE and pHi, increased PCO2 gap and intestinal net lactate production.

Conclusions: CST reflected changes in pHi, induced by intestinal hypoperfusion and at reperfusion. Levels of PSMA, pHi and PCO2 gap as indicators of aerobic conditions were defined. Dopexamine induced a decrease of PO2 TISSUE and pHi as well as an increase in lactate flux at the lowest PSMA level.

Ort, förlag, år, upplaga, sidor
Umeå: Kirurgisk och perioperativ vetenskap, 2005. s. 59
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 938
Nyckelord
Surgery, gastrointestinal tonometry, continuous, pig, pHi, intestinal ischemia, intestinal vascular bed, lactate, tissue oxygen tension, microdialysis, dopexamine, Kirurgi
Nationell ämneskategori
Kirurgi
Forskningsämne
kirurgi
Identifikatorer
urn:nbn:se:umu:diva-461 (URN)91-7305-788-6 (ISBN)
Disputation
2005-03-19, B, Tandläkarhögskolan, 9tr, Norrlands Universitetssjukhus, Umeå, 10:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2005-02-24 Skapad: 2005-02-24 Senast uppdaterad: 2009-11-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Bäcklund, TomasLindahl, Olof

Sök vidare i DiVA

Av författaren/redaktören
Bäcklund, TomasLindahl, Olof
Av organisationen
Institutionen för kirurgisk och perioperativ vetenskapRadiofysik
I samma tidskrift
Physiological Measurement

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 241 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf