Estimating Patient Organ Dosewith Computed Tomography: A Review of Present Methodologyand Required DICOM Information: A Joint Report ofAAPM Task Group 246 and the European Federationof Organizations for Medical Physics (EFOMP)
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Visa övriga samt affilieringar
2019 (Engelska)Rapport (Refereegranskat)
Abstract [en]

The purpose of this report is (1) to summarize the current state of the art in estimating organ doses from CT examinations and (2) to outline a road map for standardized reporting of essential parameters necessary for estimation of organ doses from CT imaging in the DICOM standard. To address these purposes, the report includes a comprehensive discussion of (1) the various metrics, concepts, and methods that may be used to achieve estimates of patient organ dose and (2) the DICOM standard for CT.

This Joint Report of the American Association of Physicists in Medicine (AAPM) Task Group 246 and the European Federation of Organizations for Medical Physics (EFOMP) contains three major sections and an appendix. Section 2 (with additional material in the appendix) provides a review of basic CT dosimetry metrics, their uses and limitations in the context of organ dosimetry, and the DICOM information currently associated with parameters that affect CT dose metrics and, consequently, organ dose estimates. Section 3 provides an overview of present and emerging organ dose estimation methods reported in the literature, e.g., for the lens of the eye, breast tissue, colon, and skin. Finally, the report concludes with section 4, which provides a discussion on the sources and magnitudes of uncertainty for different organ dose estimation methods.

Ongoing efforts to facilitate routine standardized estimation of patient organ doses from CT are dependent, in large part, on the availability of the DICOM Radiation Dose Structured Report (RDSR), which provides a host of information pertinent to radiation dose calculations. This report, therefore, includes detailed information on DICOM header content in CT images and how it can be used in organ dose estimation. The RDSR markedly expands the abilities of the clinical medical physicist to estimate doses at the patient, device, and protocol level

Ort, förlag, år, upplaga, sidor
Alexandria,Virginia, USA: American Association of Physicists in Medicine , 2019. , s. 46
Serie
AAPM report, ISSN 0271-7344
Nationell ämneskategori
Annan fysik
Forskningsämne
radiofysik
Identifikatorer
URN: urn:nbn:se:umu:diva-171579DOI: 10.37206/190ISBN: 978-1-936366-72-9 (digital)OAI: oai:DiVA.org:umu-171579DiVA, id: diva2:1435507
Tillgänglig från: 2020-06-05 Skapad: 2020-06-05 Senast uppdaterad: 2020-06-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Andersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Jonas
Av organisationen
Radiofysik
Annan fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 838 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf