Investigating conditional GAN performance with different generator architectures, an ensemble model, and different MR scanners for MR-sCT conversion
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0001-7119-7646
Visa övriga samt affilieringar
2020 (Engelska)Ingår i: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 65, nr 10, artikel-id 105004Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Recent developments in magnetic resonance (MR) to synthetic computed tomography (sCT) conversion have shown that treatment planning is possible without an initial planning CT. Promising conversion results have been demonstrated recently using conditional generative adversarial networks (cGANs). However, the performance is generally only tested on images from one MR scanner, which neglects the potential of neural networks to find general high-level abstract features. In this study, we explored the generalizability of the generator models, trained on a single field strength scanner, to data acquired with higher field strengths. T2-weighted 0.35T MRIs and CTs from 51 patients treated for prostate (40) and cervical cancer (11) were included. 25 of them were used to train four different generators (SE-ResNet, DenseNet, U-Net, and Embedded Net). Further, an ensemble model was created from the four network outputs. The models were validated on 16 patients from a 0.35T MR scanner. Further, the trained models were tested on the Gold Atlas dataset, containing T2-weighted MR scans of different field strengths; 1.5T(7) and 3T(12), and 10 patients from the 0.35T scanner. The sCTs were dosimetrically compared using clinical VMAT plans for all test patients. For the same scanner (0.35T), the results from the different models were comparable on the test set, with only minor differences in the mean absolute error (MAE) (35-51HU body). Similar results were obtained for conversions of 3T GE Signa and the 3T GE Discovery images (40-62HU MAE) for three of the models. However, larger differences were observed for the 1.5T images (48-65HU MAE). The overall best model was found to be the ensemble model. All dose differences were below 1%. This study shows that it is possible to generalize models trained on images of one scanner to other scanners and different field strengths. The best metric results were achieved by the combination of all networks.

Ort, förlag, år, upplaga, sidor
Institute of Physics Publishing (IOPP), 2020. Vol. 65, nr 10, artikel-id 105004
Nyckelord [en]
synthetic CTs, radiation therapy, neural networks, GANs, cGAN architecture
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-172540DOI: 10.1088/1361-6560/ab857bISI: 000536805600001PubMedID: 32235074Scopus ID: 2-s2.0-85085842867OAI: oai:DiVA.org:umu-172540DiVA, id: diva2:1449020
Tillgänglig från: 2020-06-29 Skapad: 2020-06-29 Senast uppdaterad: 2024-07-02Bibliografiskt granskad

Open Access i DiVA

fulltext(2850 kB)345 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2850 kBChecksumma SHA-512
253cb88d5ea63b367dd0efd0fc76841f769bfec86acbc710ebb0401ee4ff500e4376f5c3cf3d23fa77722ed131455dc81f83d60eb7728d1f5d3bf724feb0cb1c
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Löfstedt, TommyNyholm, Tufve

Sök vidare i DiVA

Av författaren/redaktören
Fetty, LukasLöfstedt, TommyNyholm, TufveKuess, Peter
Av organisationen
Radiofysik
I samma tidskrift
Physics in Medicine and Biology
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 345 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 501 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf