Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Novel, clinically applicable method to measure step-width during the swing phase of gait
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0001-7431-8335
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för samhällsmedicin och rehabilitering.ORCID-id: 0000-0003-1351-4425
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0003-1635-122x
Visa övriga samt affilieringar
2020 (Engelska)Ingår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 41, nr 6, artikel-id 065005Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: Step-width during walking is an indicator of stability and balance in patients with neurological disorders, and development of objective tools to measure this clinically would be a great advantage. The aim of this study was to validate an in-house-developed gait analysis system (Striton), based on optical and inertial sensors and a novel method for stride detection, for measuring step-width during the swing phase of gait and temporal parameters.

Approach: The step-width and stride-time measurements were validated in an experimental setup, against a 3D motion capture system and on an instrumented walkway. Further, test-retest and day-to-day variability were evaluated, and gait parameters were collected from 87 elderly persons (EP) and four individuals with idiopathic normal pressure hydrocephalus (iNPH) before/after surgery.

Main results: Accuracy of the step-width measurement was high: in the experimental setup mean error was 0.08 +/- 0.25 cm (R = 1.00) and against the 3D motion capture system 0.04 +/- 1.12 cm (R = 0.98). Test-retest and day-to-day measurements were equal within +/- 0.5 cm. Mean difference in stride time was -0.003 +/- 0.008 s between Striton and the instrumented walkway. The Striton system was successfully applied in the clinical setting on individuals with iNPH, which had larger step-width (6.88 cm, n = 4) compared to EP (5.22 cm, n = 87).

Significance: We conclude that Striton is a valid, reliable and wearable system for quantitative assessment of step-width and temporal parameters during gait. Initial measurements indicate that the newly defined step-width parameter differs between EP and patients with iNPH and before/after surgery. Thus, there is potential for clinical applicability in patients with reduced gait stability.

Ort, förlag, år, upplaga, sidor
Institute of Physics Publishing (IOPP), 2020. Vol. 41, nr 6, artikel-id 065005
Nyckelord [en]
gait, swing phase, step-width, inertial measurement unit, wearable, optical sensor
Nationell ämneskategori
Neurovetenskaper
Identifikatorer
URN: urn:nbn:se:umu:diva-173753DOI: 10.1088/1361-6579/ab95edISI: 000548816000001PubMedID: 32442989Scopus ID: 2-s2.0-85087528902OAI: oai:DiVA.org:umu-173753DiVA, id: diva2:1456083
Tillgänglig från: 2020-07-31 Skapad: 2020-07-31 Senast uppdaterad: 2024-07-02Bibliografiskt granskad
Ingår i avhandling
1. Wearable systems and sensors for the assessment of motor control: Development and validation of methods for clinical assessment of idiopathic normal pressure hydrocephalus
Öppna denna publikation i ny flik eller fönster >>Wearable systems and sensors for the assessment of motor control: Development and validation of methods for clinical assessment of idiopathic normal pressure hydrocephalus
2021 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Bärbara system och sensorer för bedömning av motorisk kontroll : Utveckling och validering av metoder för klinisk bedömning av idiopatisk normaltryckshydrocefalus
Abstract [en]

Human gait and balance are controlled by automatic processes in the central nervous system, and in sensory and proprioceptive systems. If a disturbance occurs in any of these complex structures, it may lead to balance and gait problems. Equally important are the systems controlling the upper extremity functions where reach, grasp and manipulation skills may be affected. For the neurodegenerative disease idiopathic normal pressure hydrocephalus (iNPH), balance and gait disturbances are cardinal symptoms. Motor control of the upper extremities is also affected. In clinic today, physical impairment of persons with iNPH is commonly visually assessed using subjective, course tests with ordinal scales with the risk of missing minor changes. There is a lack of objective and quantitative ways to measure motor control in daily patient care. The aim of this thesis was to develop and validate tools for objective assessment of parameters that affect motor control in persons with iNPH.

Postural stability in stance and walking was assessed using gyroscopes in patients with iNPH, healthy elderly (HE) and patients with ventriculomegaly (VM). Compared to HE, patients with iNPH had reduced postural stability and relied less on vision. iNPH patients also had a lower trunk sway velocity than VM during walking. The gyroscopic system could quantitatively assess postural deficits in iNPH, making it a potentially useful tool for diagnosis and for clinical follow-up. The differences found during gait also suggests that walking, rather than quiet stance, should be further investigated for facilitating differential diagnosis compared to other patient groups with ventriculomegaly.

The gait in patients with iNPH is according to guidelines defined as slow, shuffling with a low foot-lift, and wide based. To objectively quantify the latter two features, a system (Striton) was developed in-house to assess the increased distance between the feet and the peak heel-height at the push-off phase of the gait cycle. It was validated in experimental setups, compared to gold standard motion capture systems (MCS), on healthy elderly (HE), through test-retest and day-to-day evaluations, and in four patients with iNPH. Striton demonstrated high correlations, in step-width and in heel-height, compared with the MCS. The mean step-width in the HE was 5.2 ± 0.9 cm (mean±Standard Deviation) and the heel-height 16.7±0.6 cm. Test-retest and day-to-day variations were small, ±0.5 cm in step-width and ±1.2 cm in heel-height, and differences in the parameters were seen between HE and iNPH both before and after surgery. Thus, Striton has the potential of quantitatively assessing gait parameters in HE and iNPH in a valuable manner.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå Universitet, 2021. s. 50
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 2130
Nyckelord
Gait, step-width, heel-heigt, balance, trunk sway, idiopathic normal pressure hydrocephalus, IMU, Inter-rater reliability, kinematics
Nationell ämneskategori
Medicinteknik Neurologi
Forskningsämne
medicinsk informatik
Identifikatorer
urn:nbn:se:umu:diva-182784 (URN)978-91-7855-523-9 (ISBN)978-91-7855-524-6 (ISBN)
Disputation
2021-06-04, Betula, Norrlands Universitetssjukhus, Umeå, 09:00 (Svenska)
Opponent
Handledare
Anmärkning

Disputationen sänds även via Zoom.

Tillgänglig från: 2021-05-12 Skapad: 2021-05-04 Senast uppdaterad: 2021-12-06Bibliografiskt granskad

Open Access i DiVA

fulltext(4358 kB)571 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 4358 kBChecksumma SHA-512
1e2a6ac1844ea1b22b9827300eb85a331ab0b4090fb76efc2cf2ec4317d4b2fbecde891816734f80ff5b23439e1919d3b7e7bd97384e1d8f5021c27d255aac19
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Bäcklund, TomasÖhberg, FredrikJohansson, GudrunGrip, HelenaSundström, Nina

Sök vidare i DiVA

Av författaren/redaktören
Bäcklund, TomasÖhberg, FredrikJohansson, GudrunGrip, HelenaSundström, Nina
Av organisationen
RadiofysikInstitutionen för samhällsmedicin och rehabilitering
I samma tidskrift
Physiological Measurement
Neurovetenskaper

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 573 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1164 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf