Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Testing the steady-state water chemistry model predictions of pre-industrial lake pH with paleolimnological data from northern Sweden.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för ekologi, miljö och geovetenskap.
2008 (Engelska)Ingår i: Sci Total Environ, ISSN 0048-9697, Vol. 407, nr 1, s. 723-9Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Criteria are needed for distinguishing naturally acid water from that acidified by air pollution, especially in the organic-rich waters of northern Sweden. The Steady-State Water Chemistry Model (SSWC) was augmented to include organic acidity so that it could predict pre-industrial pH in organic-rich waters. The resulting model predictions of preindustrial ANC and pH were then tested against diatom predictions of pre-industrial pH and alkalinity in 58 lakes from N. Sweden (after alkalinity was converted to ANC using the CBALK method). The SSWC Model's predictions of pre-industrial lake pH in N. Sweden did not correspond well with the diatom predictions, even when accounting for the uncertainty in the diatom model. This was due to the SSWC's sensitivity to short-term fluctuations in contemporary water chemistry. Thus the SSWC Model is not suitable for judging the acidification of individual lakes in areas such as northern Sweden where the degree of chronic acidification is small, or without a good average value of contemporary water chemistry. These results should be considered when assessing the accuracy of critical loads calculated using SSWC.

Ort, förlag, år, upplaga, sidor
2008. Vol. 407, nr 1, s. 723-9
Nyckelord [en]
Critical loads, Diatoms, Pre-industrial conditions, Steady-state water chemistry model, Surface water acidification
Nationell ämneskategori
Vattenteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-11339DOI: 10.1016/j.scitotenv.2008.10.007ISI: 000261877900068PubMedID: 19004472Scopus ID: 2-s2.0-56249130043OAI: oai:DiVA.org:umu-11339DiVA, id: diva2:151010
Tillgänglig från: 2008-12-16 Skapad: 2008-12-16 Senast uppdaterad: 2023-03-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Korsman, Tom

Sök vidare i DiVA

Av författaren/redaktören
Korsman, Tom
Av organisationen
Institutionen för ekologi, miljö och geovetenskap
Vattenteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 532 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf