Umeå universitets logga

umu.sePublikationer
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Identification of single motor units in skeletal muscle under low force isometric voluntary contractions using ultrafast ultrasound
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0003-4328-5467
Department of Clinical Neurophysiology, Department of Neurosciences, University Hospital, Uppsala University, Sweden.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0003-4288-1208
2020 (Engelska)Ingår i: Scientific Reports, E-ISSN 2045-2322, Vol. 10, artikel-id 22382Artikel i tidskrift, Editorial material (Refereegranskat) Published
Abstract [en]

The central nervous system (CNS) controls skeletal muscles by the recruitment of motor units (MUs). Understanding MU function is critical in the diagnosis of neuromuscular diseases, exercise physiology and sports, and rehabilitation medicine. Recording and analyzing the MUs’ electrical depolarization is the basis for state-of-the-art methods. Ultrafast ultrasound is a method that has the potential to study MUs because of the electrical depolarizations and consequent mechanical twitches. In this study, we evaluate if single MUs and their mechanical twitches can be identified using ultrafast ultrasound imaging of voluntary contractions. We compared decomposed spatio-temporal components of ultrasound image sequences against the gold standard needle electromyography. We found that 31% of the MUs could be successfully located and their firing pattern extracted. This method allows new non-invasive opportunities to study mechanical properties of MUs and the CNS control in neuromuscular physiology.

Ort, förlag, år, upplaga, sidor
Springer Nature, 2020. Vol. 10, artikel-id 22382
Nationell ämneskategori
Fysiologi och anatomi Medicinteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-177953DOI: 10.1038/s41598-020-79863-1ISI: 000603064800003PubMedID: 33361807Scopus ID: 2-s2.0-85097985706OAI: oai:DiVA.org:umu-177953DiVA, id: diva2:1512574
Tillgänglig från: 2020-12-25 Skapad: 2020-12-25 Senast uppdaterad: 2025-02-10Bibliografiskt granskad
Ingår i avhandling
1. Identification of single motor units in ultrafast ultrasound image sequences of voluntary skeletal muscle contractions
Öppna denna publikation i ny flik eller fönster >>Identification of single motor units in ultrafast ultrasound image sequences of voluntary skeletal muscle contractions
2021 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The central nervous system controls human force production by successive recruitment of motor units in the skeletal muscles and changing their neural firing rate. The motor unit comprises a motoneuron, its innervated muscle fibers, and its axons. The motor units’ function provides the basis for diagnosing neuromuscular diseases, analysis in exercise physiology and sports science, and prosthetic control. Electromyography is the gold standard to measure and analyze motor units under voluntary contractions, but the technique is limited in its field of view. Recent studies have demonstrated the possibility of using imaging techniques to study motor units providing a large field of view. However, these studies are based on electrical stimulation of the muscle, and therefore only provide partial information on the motor unit’s function in contrast to voluntary contractions. 

The overall purpose of this thesis was to develop methods to identify and analyze motor units in ultrafast ultrasound image sequences of voluntary skeletal muscle contractions for neuromuscular diagnostics and muscle contraction characterization. The thesis is based on four studies. 

In the first study, a methodological pipeline was developed to identify motor units by decomposing image sequences into spatiotemporal components. The firing pattern and territory of the components were evaluated using an in-house developed simulation model. It showed that this pipeline identified 75-95% of the simulated motor units at low force levels. The territory estimation had a 50-80% sensitivity and 100% specificity, and the firing pattern estimation had a 90% agreement with the true firing pattern. In general, the method’s performance decreased for more than 20 active motor units. Experimental isometric contractions from healthy subjects were recorded for feasibility assessment. The results showed that the number of components increased with force level, where the number of components at 1%, 2.5%, and 5% maximal voluntary contraction averaged 7, 9, and 12, respectively. The territory diameter (5-6 mm), contraction duration (40-50 ms), and firing rate (11-12 Hz) were similar for all force levels. Thus, the results were similar to motor units’ known characteristics, suggesting that these components could be motor units. 

In the second study, the proposed pipeline was validated using ultrafast ultrasound and state-of-the-art needle electromyography simultaneously. The results showed that the method could identify 31% of the motor units in low force voluntary isometric contractions, and possible explanations for the unidentified 69% were discussed. The conclusion was that the proposed pipeline can identify motor units.

The third study focused on evaluating the influence of different decomposition algorithms on performance of identifying single motor units in the data from study 2. The results showed that a decomposition algorithm is required for motor unit identification. The algorithms performed similarly in estimating firing patterns and they did not influence the motor unit twitch waveform. It was also shown that the algorithms identify different motor units, where some identified completely different units. These results suggest that the precise choice of decomposition algorithm is not critical, and there may be an improvement potential to detect more motor units. 

In the fourth study, data from the second study was used to estimate single motor units’ contractile parameters based on a subset of the data (14 motor unit contractions). Multiple single motor unit’s contraction parameters were estimated using two models. Both models’ contractile parameters were consistent and agreed with previous literature. The former and more detailed model had a better experimental fit, whereas the latter model captured the “average behavior” with fewer parameters. It was found that the single twitch waveforms within a motor unit change shape during a voluntary isometric contraction at a low force level. These results suggest that the motor unit’s contractile parameters can be estimated using ultrafast ultrasound image sequences in voluntary isometric contractions. 

In summary, a methodological pipeline to identify motor units was developed, evaluated, and validated. The key module in the pipeline, i.e., decomposition algorithm, was evaluated by comparing different algorithms’ influence on identifying single motor units. Finally, the pipeline output can be used for estimating motor units’ contractile parameters. This pipeline may contribute to neuromuscular diagnostics and muscle contraction characterization. In general, it may allow the study of various motor unit-related questions that previously were difficult or not possible to address. 

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, 2021. s. 68
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 2127
Nyckelord
ultrafast ultrasound, motor units, decomposition, skeletal muscle, voluntary contractions, electromyography, twitch, imaging
Nationell ämneskategori
Fysiologi och anatomi Medicinsk bildvetenskap
Identifikatorer
urn:nbn:se:umu:diva-187016 (URN)978-91-7855-586-4 (ISBN)978-91-7855-587-1 (ISBN)
Disputation
2021-09-22, Bergasalen, Norrlands universitetssjukhus, Umeå, 13:00 (Engelska)
Opponent
Handledare
Forskningsfinansiär
Vetenskapsrådet, 2015-04461
Tillgänglig från: 2021-09-01 Skapad: 2021-08-30 Senast uppdaterad: 2025-02-10Bibliografiskt granskad

Open Access i DiVA

fulltext(4362 kB)266 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 4362 kBChecksumma SHA-512
605dddff6d0d13f046068945a0eb023ed44e5f9304f70a10a6d26123f306a1494abf366629930ca2fec8de73bbda42d3594df152758cdf79b0a96793c04c3dd1
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Rohlén, RobinGrönlund, Christer

Sök vidare i DiVA

Av författaren/redaktören
Rohlén, RobinGrönlund, Christer
Av organisationen
Radiofysik
I samma tidskrift
Scientific Reports
Fysiologi och anatomiMedicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 267 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 700 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf