Reduction of fluoroscopy duration in radiofrequency ablation obtained by the use of a non-fluoroscopic catheter navigation system.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
Visa övriga samt affilieringar
2006 (Engelska)Ingår i: Europace, Vol. 8, nr 12, s. 1027-30Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

AIMS: Radiofrequency (RF) ablation requires placement of several catheters at critical positions. The catheters are positioned with fluoroscopy, resulting in a significant radiation exposure. We have investigated to what degree an intracardiac navigation system reduces the fluoroscopy duration in different groups of routine RF ablations. METHODS AND RESULTS: The fluoroscopy time was evaluated in 365 consecutive routine RF ablations, performed between 2002 and 2005. An intracardiac navigation system (LocaLisa, Medtronic) was used from 2003. The data were prospectively entered into a database and subsequently retrieved, and the procedures classified as being performed with fluoroscopy only or with the aid of the LocaLisa system. After introduction of the LocaLisa system, the median fluoroscopy time decreased from 24 to 10 min in the 141 atrioventricular nodal re-entry tachycardia (AVNRT) ablations and from 43 to 28 min in the 71 atrial flutter (AFl) ablations (P<0.005 for both). In the 145 Wolff-Parkinson-White (WPW) ablations, a decrease from 27 to 23 min was observed (P=0.03). The decrease in AVNRT and AFl, but not in WPW was associated with the introduction of the LocaLisa system. CONCLUSION: The use of the LocaLisa system during RF ablations significantly reduced the fluoroscopy time in AVNRT and AFl ablations, by a median of 58% and 46%, respectively.

Ort, förlag, år, upplaga, sidor
2006. Vol. 8, nr 12, s. 1027-30
Identifikatorer
URN: urn:nbn:se:umu:diva-16129DOI: 10.1093/europace/eul127PubMedID: 17101627OAI: oai:DiVA.org:umu-16129DiVA, id: diva2:155802
Tillgänglig från: 2007-08-17 Skapad: 2007-08-17 Senast uppdaterad: 2022-10-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Person

Kesek, MilosRönn, FolkeHöglund, NiklasJensen, Steen

Sök vidare i DiVA

Av författaren/redaktören
Kesek, MilosRönn, FolkeHöglund, NiklasJensen, Steen
Av organisationen
Medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 165 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf