Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors
Radiology Department, Complutense University, Madrid, Spain.
Université de Paris, 12 Rue de l’École de Médecine, Paris, France.
Institute of Medical Physics, Hospital Nuremberg, Prof.-Ernst-Nathan-Str. 1, Nuremberg, Germany.
ESTESC-Coimbra Health School, Medical Imaging and Radiotherapy Department, Instituto Politécnico de Coimbra, Rua 5 de Outubro, S. Martinho Do Bispo, Coimbra, Portugal.
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Insights into Imaging, E-ISSN 1869-4101, Vol. 12, nr 1, artikel-id 99Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

This review presents basic information on the dosimetric quantities used in medical imaging for reporting patient doses and establishing diagnostic reference levels. The proper use of the radiation protection quantity “effective dose” to compare doses delivered by different radiological procedures and different imaging modalities with its uncertainties and limitations, is summarised. The estimates of population doses required by the European Directive on Basic Safety Standards is commented on. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits. The application of effective dose on the cumulative doses from recurrent imaging procedures is also discussed.

Patient summary: Basic information on the measurement units (dosimetric quantities) used in medical imaging for reporting radiation doses should be understandable to patients. The Working Group on “Dosimetry for imaging in clinical practice” recommended that a brief explanation on the used dosimetric quantities and units included in the examination imaging report, should be available for patients. The use of the quantity “effective dose” to compare doses to which patients are exposed to from different radiological procedures and its uncertainties and limitations, should also be explained in plain language. This is also relevant for the dialog on to the cumulative doses from recurrent imaging procedures. The paper summarises these concepts, including the need to estimate the population doses required by the European Directive on Basic Safety Standards. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits.

Ort, förlag, år, upplaga, sidor
Springer Berlin/Heidelberg, 2021. Vol. 12, nr 1, artikel-id 99
Nyckelord [en]
Cumulative dose, Diagnostic reference levels, Dosimetric quantities, Effective dose, Patient information
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-186542DOI: 10.1186/s13244-021-01041-2ISI: 000675243700002Scopus ID: 2-s2.0-85111777551OAI: oai:DiVA.org:umu-186542DiVA, id: diva2:1586656
Tillgänglig från: 2021-08-20 Skapad: 2021-08-20 Senast uppdaterad: 2024-04-05Bibliografiskt granskad

Open Access i DiVA

fulltext(1086 kB)140 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1086 kBChecksumma SHA-512
ca8cd8a6f1cabf59b130b6b2bffa15ba1116bc5128dd985820fc9967a78960dda1f259f9ee4346ee3ee3565e188e8f3c30fca8a3283e203cd5da74745f5cc32a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Andersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Jonas
Av organisationen
Radiofysik
I samma tidskrift
Insights into Imaging
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 141 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 401 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf