Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
An optical pascal in Sweden
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik. Measurement Science and Technology, Rise Research Institutes of Sweden, Borås, Sweden.ORCID-id: 0000-0001-6824-3111
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik.ORCID-id: 0000-0001-5790-2185
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik.ORCID-id: 0000-0002-3261-9903
Measurement Science and Technology, Rise Research Institutes of Sweden, Borås, Sweden.
Visa övriga samt affilieringar
2022 (Engelska)Ingår i: Journal of Optics, ISSN 2040-8978, E-ISSN 2040-8986, Vol. 24, nr 3, artikel-id 033002Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

By measuring the refractivity and the temperature of a gas, its pressure can be assessed from fundamental principles. The highest performing instruments are based on Fabry-Perot cavities where a laser is used to probe the frequency of a cavity mode, which is shifted in relation to the refractivity of the gas in the cavity. Recent activities have indicated that such systems can demonstrate an extended uncertainty in the 10 ppm (parts-per-million or 10-6) range. As a means to reduce the influence of various types of disturbances (primarily drifts and fluctuations) a methodology based on modulation, denoted gas modulation refractometry (GAMOR), has recently been developed. Systems based on this methodology are in general high-performance, e.g. they have demonstrated precision in the sub-ppm range, and they are sturdy. They can also be made autonomous, allowing for automated and unattended operation for virtually infinite periods of time. To a large degree, the development of such instruments depends on the access to modern photonic components, e.g. narrow line-width lasers, electro-and acousto-optic components, and various types of fiber components. This work highlights the role of such modern devices in GAMOR-based instrumentation and provides a review on the recent development of such instruments in Sweden that has been carried out in a close collaboration between a research institute and the Academy. It is shown that the use of state-of-the-art photonic devices allows sturdy, automated and miniaturized instrumentation that, for the benefit of industry, can serve as standards for pressure and provide fast, unattended, and calibration-free pressure assessments at a fraction of the present cost.

Ort, förlag, år, upplaga, sidor
Institute of Physics (IOP), 2022. Vol. 24, nr 3, artikel-id 033002
Nyckelord [en]
Fabry-Perot, optical, pascal, pressure, refractometry, Sweden
Nationell ämneskategori
Atom- och molekylfysik och optik Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:umu:diva-193176DOI: 10.1088/2040-8986/ac4ea2ISI: 000757597100001Scopus ID: 2-s2.0-85125850587OAI: oai:DiVA.org:umu-193176DiVA, id: diva2:1645453
Forskningsfinansiär
Vinnova, 2017-05013Vinnova, 2018-04570Vinnova, 2019-05029Vetenskapsrådet, 621-2020-05105Vetenskapsrådet, 621-2015-04374Kempestiftelserna, 1823.U12EU, Horisont 2020Tillgänglig från: 2022-03-17 Skapad: 2022-03-17 Senast uppdaterad: 2023-09-06Bibliografiskt granskad
Ingår i avhandling
1. Fabry-Pérot based refractometry: development of a transportable refractometer for assessment of gas pressure
Öppna denna publikation i ny flik eller fönster >>Fabry-Pérot based refractometry: development of a transportable refractometer for assessment of gas pressure
2023 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Fabry-Pérot-baserad refraktometri : utveckling av en transporterbar refraktometer för mätning av gastryck
Abstract [en]

A unified description of physical phenomena through measurement science is one of the foundational pillars in a global society. The International System of Units (SI) is the most widely used system of units and since its redefinition in 2019, all units encompassed by it are based on fundamental physical constants. The units of the SI, such as the second, metre, and kilogram, are realized by the use of primary standards which are used, through calibration chains, to certify the accuracy of measuring devices in our society. Its redefinition enabled the realization of the SI-unit for pressure (pascal) in a novel way; instead of force per area (N/m2), it can alternatively be defined as an energy density (J/m3). Subsequently, this opened up for the use of optical realizations of the pascal (Pa). It has been prophesied that a possible means to do this is by assessing refractivity through the use of Fabry-Pérot (FP) refractometry. Although such instrumentation indeed can assess refractivity, it has unfortunately been found that they in practice are affected by various types of disturbances that aggravate assessments with the required uncertainty.

This thesis describes the development of FP-based refractometers utilizing a novel measurement methodology, denoted gas modulation refractometry (GAMOR). By the use of rapid gas modulation and baseline interpolation, GAMOR has the ability to significantly reduce the influence of various types of disturbances, not least drifts and fluctuations. From this, two FP-based refractometers have been developed; one stationary, denoted the SOP, capable of assessing pressure with an uncertainty of [(10 mPa)2 + (10 × 10−6·P)2]1/2, and one transportable, denoted the TOP, with an uncertainty of [(16 mPa)2 + (28 × 10−6·P)2]1/2. Furthermore, it was shown that their mutual short-term precision is excellent, with a deviation of only 0.04 ppm when simultaneously assessing a pressure of 16 kPa.

A major part of this thesis was devoted to the construction of the TOP and an investigation of its transportability and performance. It was used in a ring comparison with various pressure standards at four European national metrology institutes. It was concluded that, despite being transported, the performance remained virtually unchanged, and that, in the 10 – 90 kPa range, all the standards agreed within their uncertainties.

These results indicate that FP-based refractometers utilizing the GAMOR methodology have the potential to act as transportable standards based on fundamental physical constants and paves the way for future research within the field.

Abstract [sv]

En av grundpelarna i ett globalt samhälle är en enad syn på fysikaliska fenomen med förankring i vetenskap. Det Internationella måttenhetssystemet (SI) är det mest använda enhetssystemet och sedan dess omdefiniering 2019 är alla dess enheter baserade på grundläggande fysikaliska konstanter. SI-enheterna, som exempelvis sekund, meter och kilogram, realiseras genom primära standarder. Dessa standarder används, via kalibreringskedjor, för att certifiera noggrannheten av mätinstrument runtom vårt samhälle. Omdefiniering ledde till möjligheten att realisera enheten för tryck (pascal) på ett nytt sätt; i stället för kraft per area (N/m2) går det numera att definiera tryck som energidensitet (J/m3). Detta ledde i sin tur till att optiska realiseringar av pascal (Pa) för gastryck blev en möjlighet. Det har påvisats att detta kan uppnås genom att mäta refraktivitet med hjälp av Fabry-Pérot (FP)-refraktometri. Även om denna teknik kan användas för att bestämma refraktivitet, påverkas den i praktiken av diverse störningar vilket försvårar den nogrannhet som krävs för att ersätta dagens mekaniska tryckstandarder.

I denna avhandling beskrivs utvecklingen av FP-baserade refraktometrar som använder sig av en av oss nyutvecklad mätteknik; gasmodulationsrefraktometri (GAMOR). Tekniken bygger på en snabb modulering av gas och baslinje-interpolering, vilket reducerar effekten av snabba likaväl som långsamma störningar. Baserat på detta har två refraktometrar utvecklats; en stationär, SOP, som kan mäta tryck med en osäkerhet på [(10 mPa)2 + (10 × 10−6·P)2]1/2, samt en transportabel, TOP, med en osäkerhet på [(16 mPa)2 + (28 × 10−6·P)2]1/2. Vidare har det visats att deras inbördes korttidsprecision är utmärkt, med en avvikelse på endast 0.04 ppm när de samtidigt mätte ett tryck på 16 kPa.

En signifikant del av denna avhandling har ägnats till att konstruera TOP:en, samt att undersöka dess transporterbarhet och prestanda. Den användes i en serie jämförelsemätningar av olika tryckstandarder där fyra europeiska nationella metrologiska institut deltog. Från dessa mätningar konstaterades det att TOP:ens prestanda inte påverkades av transporten och att tryckstandarderna, inom det spann som undersöktes, 10 – 90 kPa, överensstämde inom deras osäkerheter.

Resultaten som presenteras tyder på att FP-baserade refraktometrar som använder sig av GAMOR-metodiken har potentialen att kunna agera som transportabla standarder baserade på grundläggande fysikaliska konstanter, något som banar vägen för framtida forskning inom området.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, 2023. s. 95
Nyckelord
fabry-pérot, refractometry, optical resonator, transportable, pressure standard, gamor, pressure, metrology, ring comparison, si, pascal, quantumpascal
Nationell ämneskategori
Atom- och molekylfysik och optik
Forskningsämne
fysik
Identifikatorer
urn:nbn:se:umu:diva-214141 (URN)9789180701570 (ISBN)9789180701563 (ISBN)
Disputation
2023-10-02, NAT.D.440, Naturvetarhuset, Umeå, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2023-09-11 Skapad: 2023-09-06 Senast uppdaterad: 2023-09-07Bibliografiskt granskad

Open Access i DiVA

fulltext(16086 kB)280 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 16086 kBChecksumma SHA-512
308e7ef262727685125b345ee2477cf25af591ad446f8d2dc6877770dde878322c438b7294736a413ee1886d2cb4f89125c7d59eef7ab905fc00c44fabcbbd79
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Forssén, ClaytonSilander, IsakZakrisson, JohanAxner, Ove

Sök vidare i DiVA

Av författaren/redaktören
Forssén, ClaytonSilander, IsakZakrisson, JohanAxner, Ove
Av organisationen
Institutionen för fysik
I samma tidskrift
Journal of Optics
Atom- och molekylfysik och optikAnnan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 280 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 664 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf