Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures
Visa övriga samt affilieringar
2022 (Engelska)Ingår i: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 32, s. 5525-5531Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The terms "notifications" and "alerts" for medical exposures are used by several national and international organisations. Recommendations for CT scanners have been published by the American Association of Physicists in Medicine. Some interventional radiology societies as well as national authorities have also published dose notifications for fluoroscopy-guided interventional procedures. Notifications and alerts may also be useful for optimisation and to avoid unintended and accidental exposures. The main interest in using these values for high-dose procedures (CT and interventional) is to optimise imaging procedures, reducing the probability of stochastic effects and avoiding tissue reactions. Alerts in X-ray systems may be considered before procedures (as in CT), during procedures (in some interventional radiology systems), and after procedures, when the patient radiation dose results are known and processed. This review summarises the different uses of notifications and alerts to help in optimisation for CT and for fluoroscopy-guided interventional procedures as well as in the analysis of unintended and accidental medical exposures. The paper also includes cautions in setting the alert values and discusses the benefits of using patient dose management systems for the alerts, their registry and follow-up, and the differences between notifications, alerts, and trigger levels for individual procedures and the terms used for the collective approach, such as diagnostic reference levels.

Key points:

• Notifications and alerts on patient dose values for computed tomography (CT) and fluoroscopy-guided interventional procedures (FGIP) allow to improve radiation safety and contribute to the avoidance of radiation injuries and unintended and accidental exposures.

• Alerts may be established before the imaging procedures (as in CT) or during and after the procedures as for FGIP.

• Dose management systems should include notifications and alerts and their registry for the hospital quality programmes.

Ort, förlag, år, upplaga, sidor
Springer, 2022. Vol. 32, s. 5525-5531
Nyckelord [en]
Alert, Fluoroscopy-guided interventional procedures, Notification, Tomography, X-ray computed, Unintended exposures
Nationell ämneskategori
Radiologi och bildbehandling
Forskningsämne
radiologi
Identifikatorer
URN: urn:nbn:se:umu:diva-193495DOI: 10.1007/s00330-022-08675-wISI: 000769890000003PubMedID: 35294584Scopus ID: 2-s2.0-85126673383OAI: oai:DiVA.org:umu-193495DiVA, id: diva2:1649777
Tillgänglig från: 2022-04-04 Skapad: 2022-04-04 Senast uppdaterad: 2022-11-30Bibliografiskt granskad

Open Access i DiVA

fulltext(248 kB)120 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 248 kBChecksumma SHA-512
21720b46364039289a20f3f1b49741eaff31953a5560f16d80c9959ed4e303f84489163c0ea58c86e29d38363913c2b9f2d8d4d8ccf64f5ce6fd4de71719c624
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Andersson, Jonas S.

Sök vidare i DiVA

Av författaren/redaktören
Vano, EliseoAndersson, Jonas S.
Av organisationen
Radiofysik
I samma tidskrift
European Radiology
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 165 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 411 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf