Influence of finite-sized detection solid angle on bidirectional reflectance distribution function measurements
Department of Natural Sciences, Digital Printing Center, Mid Sweden University, Örnsköldsvik, Sweden.
Department of Natural Sciences, Mid Sweden University, Härnösand, Sweden.ORCID-id: 0000-0002-3599-9374
Department of Natural Sciences, Digital Printing Center, Mid Sweden University, Örnsköldsvik, Sweden.
Department of Natural Sciences, Mid Sweden University, Härnösand, Sweden.ORCID-id: 0000-0002-0529-1009
2014 (Engelska)Ingår i: Applied Optics, ISSN 1559-128X, E-ISSN 2155-3165, Vol. 53, nr 6, s. 1212-1220Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper deals with limitations and often overlooked sources of error introduced in compact double-beam goniophotometers. It is shown that relative errors in measured radiance factor, comparable to the total measurement uncertainty, can be introduced if recommended corrections are not carried out. Two different error sources are investigated, both related to the size of the detection solid angle. The first is a geometrical error that occurs when the size of the illuminated area and detector aperture are comparable to the distance between them. The second is a convolution error due to variations in radiant flux over the detector aperture, which is quantified by simulating the full 3D bidirectional reflectance distribution function (BRDF) of a set of samples with different degrees of anisotropic reflectance. The evaluation is performed for a compact double-beam goniophotometer using different detection solid angles, and it is shown that both error sources introduce relative errors of 1%–3%, depending on viewing angle and optical properties of the sample. Commercially available compact goniophotometers, capable of absolute measurements, are becoming more and more common, and the findings in this paper are therefore important for anyone using or planning to use this type of instrument.

Ort, förlag, år, upplaga, sidor
Optical Society of America, 2014. Vol. 53, nr 6, s. 1212-1220
Nyckelord [en]
Reflection, Scattering measurements, BRDF, turbid media
Nationell ämneskategori
Annan naturvetenskap
Identifikatorer
URN: urn:nbn:se:umu:diva-195518DOI: 10.1364/AO.53.001212ISI: 000331949600027Scopus ID: 2-s2.0-84942366011OAI: oai:DiVA.org:umu-195518DiVA, id: diva2:1661877
Tillgänglig från: 2022-05-30 Skapad: 2022-05-30 Senast uppdaterad: 2022-05-31Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Johansson, NiklasNeuman, MagnusAndersson, MattiasEdström, Per

Sök vidare i DiVA

Av författaren/redaktören
Johansson, NiklasNeuman, MagnusAndersson, MattiasEdström, Per
I samma tidskrift
Applied Optics
Annan naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 134 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-6th-edition.csl
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf