Repository of intra-and inter-run variations of quantitative autoantibody assays: A European multicenter study
Laboratoire d'Immunologie, Hôpital Européen Georges Pompidou, APHP, Université de Paris Cité, Paris, France.
Laboratory of Clinical Pathology, San Antonio Hospital, Azienda Sanitaria Universitaria Integrata, Udine, Italy.
Cerballiance, Lisses, France.
Section of Protein Allergy and Immunology, Laboratory Medicine Department, Diagnostic Clinic, University Hospital of North Norway, Tromsø, Norway.
Show others and affiliations
2022 (English)In: Clinical Chemistry and Laboratory Medicine, ISSN 1434-6621, E-ISSN 1437-4331, Vol. 60, no 9, p. 1373-1383Article in journal (Refereed) Published
Abstract [en]

No reference data are available on repositories to measure precision of autoantibody assays. The scope of this study was to document inter-and intra-run variations of quantitative autoantibody assays based on a real-world large international data set. Members of the European Autoimmunity Standardisation Initiative (EASI) group collected the data of intra-and inter-run variability obtained with assays quantifying 15 different autoantibodies in voluntary participating laboratories from their country. We analyzed the impact on the assay performances of the type of immunoassay, the number of measurements used to calculate the coefficient of variation (CVs), the nature and the autoantibody level of the internal quality control (IQC). Data were obtained from 64 laboratories from 15 European countries between February and October 2021. We analyzed 686 and 1,331 values of intra-and inter-run CVs, respectively. Both CVs were significantly dependent on: The method of immunoassay, the level of IQC with higher imprecision observed when the antibody levels were lower than 2-fold the threshold for positivity, and the nature of the IQC with commercial IQCs having lower CVs than patients-derived IQCs. Our analyses also show that the type of autoantibody has low impact on the assay' performances and that 15 measurements are sufficient to establish reliable intra-and inter-run variations. This study provides for the first time an international repository yielding values of intra-and inter-run variation for quantitative autoantibody assays. These data could be useful for ISO 15189 accreditation requirements and will allow clinical diagnostic laboratories to assure quality of patient results.

Place, publisher, year, edition, pages
De Gruyter Open, 2022. Vol. 60, no 9, p. 1373-1383
Keywords [en]
immunoassay, inter-run variation, internal quality control, intra-run variation, laboratory accreditation, precision, quality assurance
National Category
Clinical Laboratory Medicine
Identifiers
URN: urn:nbn:se:umu:diva-198043DOI: 10.1515/cclm-2022-0411ISI: 000815270400001PubMedID: 35749077Scopus ID: 2-s2.0-85133542085OAI: oai:DiVA.org:umu-198043DiVA, id: diva2:1683309
Available from: 2022-07-15 Created: 2022-07-15 Last updated: 2022-12-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Eriksson, Catharina

Search in DiVA

By author/editor
Eriksson, Catharina
By organisation
Clinical Immunology
In the same journal
Clinical Chemistry and Laboratory Medicine
Clinical Laboratory Medicine

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 284 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf