Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Validation of dynamic [18F]FE-PE2I PET for estimation of relative regional cerebral blood flow: a comparison with [15O]H2O PET
Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0002-3731-3612
Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).ORCID-id: 0000-0001-6169-5836
Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.ORCID-id: 0000-0001-5227-8117
2022 (Engelska)Ingår i: EJNMMI Research, E-ISSN 2191-219X, Vol. 12, nr 1, artikel-id 72Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Dopamine transporter (DAT) imaging is used in the diagnostic work-up in suspected parkinsonian syndromes and dementia with Lewy bodies but cannot differentiate between these syndromes, and an extra brain imaging examination of the regional cerebral blood flow (rCBF) or glucose metabolism is often needed for differential diagnosis. The requirement of two different imaging examinations is resource-consuming and inconvenient for the patients. Therefore, imaging of both cortical blood flow and DAT imaging with the same radiotracer would be more convenient and cost-effective. The aim of this study was to test whether relative regional cerebral blood flow (rCBFR) can be measured with the DAT-specific positron emission tomography (PET) tracer [18F]FE-PE2I (FE-PE2I), by validation with cerebral perfusion measured with [15O]H2O PET (H2O).

Methods: The rCBFR was quantified by kinetic modeling for FE-PE2I (R1) and H2O (F). The R1 was calculated using the simplified reference tissue model, and F was calculated with a modified Koopman double-integration method. The linear relationship and intraclass correlation (ICC) between R1 and F were tested in image data derived from 29 patients with recent onset parkinsonism and 30 healthy controls.

Results: There was a strong linear correlation across all subjects between R1 and F in the frontal, parietal, temporal, cingulate and occipital cortex as well as in the striatum (r ≥ 0.731–0.905, p < 0.001) with a good-to-excellent ICC, ranging from 0.727 to 0.943 (p < 0.001).

Conclusions: Our results suggest that FE-PE2I may be used as a proxy for cerebral perfusion, thus potentially serving as a radiotracer for assessment of both DAT availability and rCBFR in one single dynamic scan. This could be valuable in the differential diagnosis of parkinsonian syndromes.

Trial registration: EUDRA-CT 2015-003045-26. Registered 23 October 2015 https://www.clinicaltrialsregister.eu/ctr-search/search?query=2015-003045-26

Ort, förlag, år, upplaga, sidor
Springer Science+Business Media B.V., 2022. Vol. 12, nr 1, artikel-id 72
Nyckelord [en]
15O H2O, 18F FE-PE2, Cerebral blood flow, Cerebral perfusion, Parkinsonian syndromes, Parkinsonism, Positron emission tomography
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-201365DOI: 10.1186/s13550-022-00941-8ISI: 000886120800001Scopus ID: 2-s2.0-85142139428OAI: oai:DiVA.org:umu-201365DiVA, id: diva2:1715283
Forskningsfinansiär
Region VästerbottenParkinsonfondenTillgänglig från: 2022-12-01 Skapad: 2022-12-01 Senast uppdaterad: 2023-09-05Bibliografiskt granskad

Open Access i DiVA

fulltext(2608 kB)131 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2608 kBChecksumma SHA-512
e84dd69c9e964c888485f9938cbb549db1bf36f2b420f380cb1f17e8078eca9ff80a0860f5e57de97540bc1a1c6de18cb1da630ff249fe563103ff9aa41d99e9
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Jakobson Mo, SusannaAxelsson, JanJonasson, Lars S.Riklund, Katrine

Sök vidare i DiVA

Av författaren/redaktören
Jakobson Mo, SusannaAxelsson, JanJonasson, Lars S.Riklund, Katrine
Av organisationen
Umeå centrum för funktionell hjärnavbildning (UFBI)Diagnostisk radiologiRadiofysikInstitutionen för integrativ medicinsk biologi (IMB)
I samma tidskrift
EJNMMI Research
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 131 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 304 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf