Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Salivary cortisol and cortisone in diagnosis of Cushing's syndrome: a comparison of six different analytical methods
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin.ORCID-id: 0000-0003-2110-4602
Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Klinisk kemi.ORCID-id: 0000-0001-9474-6513
Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Klinisk kemi.
Department of Clinical Chemistry, Linköping University, Linköping, Sweden; Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Clinical Chemistry and Laboratory Medicine, ISSN 1434-6621, E-ISSN 1437-4331, Vol. 61, nr 10, s. 1780-1791Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: Salivary cortisol and cortisone at late night and after dexamethasone suppression test (DST) are increasingly used for screening of Cushing’s syndrome (CS). We aimed to establish reference intervals for salivary cortisol and cortisone with three liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques and for salivary cortisol with three immunoassays (IAs), and evaluate their diagnostic accuracy for CS.

Methods: Salivary samples at 08:00 h, 23:00 h and 08:00 h after a 1-mg DST were collected from a reference population (n=155) and patients with CS (n=22). Sample aliquots were analyzed by three LC-MS/MS and three IA methods. After establishing reference intervals, the upper reference limit (URL) for each method was used to calculate sensitivity and specificity for CS. Diagnostic accuracy was evaluated by comparing ROC curves.

Results: URLs for salivary cortisol at 23:00 h were similar for the LC-MS/MS methods (3.4–3.9 nmol/L), but varied between IAs: Roche (5.8 nmol/L), Salimetrics (4.3 nmol/L), Cisbio (21.6 nmol/L). Corresponding URLs after DST were 0.7–1.0, and 2.4, 4.0 and 5.4 nmol/L, respectively. Salivary cortisone URLs were 13.5–16.6 nmol/L at 23:00 h and 3.0–3.5 nmol/L at 08:00 h after DST. All methods had ROC AUCs ≥0.96.

Conclusions: We present robust reference intervals for salivary cortisol and cortisone at 08:00 h, 23:00 h and 08:00 h after DST for several clinically used methods. The similarities between LC-MS/MS methods allows for direct comparison of absolute values. Diagnostic accuracy for CS was high for all salivary cortisol and cortisone LC-MS/MS methods and salivary cortisol IAs evaluated.

Ort, förlag, år, upplaga, sidor
Walter de Gruyter, 2023. Vol. 61, nr 10, s. 1780-1791
Nyckelord [en]
Cushing's syndrome, immunoassay, LC-MS/MS, method comparison, salivary cortisol, salivary cortisone
Nationell ämneskategori
Analytisk kemi Endokrinologi och diabetes
Identifikatorer
URN: urn:nbn:se:umu:diva-206793DOI: 10.1515/cclm-2023-0141ISI: 000964106600001PubMedID: 37013440Scopus ID: 2-s2.0-85151863068OAI: oai:DiVA.org:umu-206793DiVA, id: diva2:1752564
Forskningsfinansiär
Region VästerbottenTillgänglig från: 2023-04-24 Skapad: 2023-04-24 Senast uppdaterad: 2024-09-26Bibliografiskt granskad
Ingår i avhandling
1. Diagnosing hyper- and hypocortisolism using saliva samples: pitfalls and how to avoid them
Öppna denna publikation i ny flik eller fönster >>Diagnosing hyper- and hypocortisolism using saliva samples: pitfalls and how to avoid them
2023 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Alternativ titel[sv]
Biokemisk diagnostik av hyper- och hypokortisolism med salivprover : fallgropar och hur man undviker dem
Abstract [en]

Background: Cushing's syndrome (CS) is caused by high cortisol secretion whereas insufficient cortisol secretion is called adrenal insufficiency (AI). Both are rare diseases with substantial diagnostic delay, and high morbidity and mortality even though effective treatment is available. This thesis aims to improve diagnostic tests for CS and AI using analyses of cortisol and its inactive metabolite cortisone in saliva samples.

Methods: Papers 1 and 2 are based on a reference cohort including 155 individuals and 22 patients with CS. Salivary samples were collected at late-night (23:00 hours ± 15 minutes) and after a 1-mg overnight dexamethasone suppression test (DST). In Paper 1, reference intervals for salivary cortisol and cortisone analyzed with liquid chromatography-tandem mass spectrometry (LC-MS/MS) were established for late-night and post-DST samples. Diagnostic accuracy for CS was calculated using the established reference intervals. Potential effects of age, comorbidities, season, and sampling time point were also studied. In Paper 2, different analytical methods for measurement of salivary cortisol (3 LC-MS/MS and 3 immunoassays) and salivary cortisone (3 LC-MS/MS assays) were compared regarding reference intervals and diagnostic accuracies for CS. Paper 3 elucidated the potential effect of liquorice consumption, blood contamination, and topical hydrocortisone handling prior to sampling on salivary cortisol and cortisone. Paper 4 investigated whether salivary cortisol and cortisone are less affected than plasma cortisol by estrogen-containing oral contraceptive (OCs) in women undergoing a short Synacthen test (SST) by comparing the response in women with (n=41) and without OCs (n=46).

Results: Paper 1 established reference intervals for salivary cortisol and cortisone at 23:00 hours and after DST. Using the upper reference limits as cut-offs, the diagnostic tests rendered high diagnostic accuracy for CS using salivary cortisol (sensitivity 90–95 %, specificity 96 %). There was no seasonal variation and no significant difference between samples collected at 22:00 vs 23:00 hours. Salivary cortisone showed a higher diagnostic accuracy for CS (sensitivity 100 % and specificity 94–95 %) and was less affected by other comorbidities compared to salivary cortisol. Paper 2 showed very high agreement between the three LC-MS/MS methods and that measuring salivary cortisol with immunoassays resulted in higher cortisol concentrations than with LC-MS/MS. However, using the newly established reference limits for each method, all had high diagnostic accuracy for CS. Late-night salivary cortisone analyzed with the LC-MS/MS methods and salivary cortisol analyzed with the Roche immunoassay showed the highest diagnostic accuracies. Paper 3 showed that liquorice consumption increased late-night salivary cortisol, which was sustained for up to 6 days, whereas no effect was seen on salivary cortisone. Salivary cortisol, but not cortisone, was increased by contamination of saliva with ≥0.5 % blood, which could be revealed by a clearly visible red discoloration of the saliva. Handling of topical hydrocortisone before saliva sampling affected salivary cortisol to a much higher degree than salivary cortisone. Paper 4 showed that women using OCs have considerably higher plasma cortisol levels during an SST, whereas salivary cortisol and salivary cortisone were lower compared to controls. However, the lower reference limits were not significantly different for salivary measurands, with salivary cortisone slightly more robust, opting for a common cut-off to exclude AI regardless of OCs.

Conclusion: Using the reference intervals calculated for several clinically used analytical methods showed high diagnostic accuracy for CS, with cortisone showing the highest accuracy. Analyzing salivary cortisone was not affected by liquorice consumption or blood contamination. Salivary cortisone was least affected by OCs during an SST. In summary, salivary cortisone is very useful in the diagnostic work-up for CS and AI.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, 2023. s. 72
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 2237
Nyckelord
Cushing's syndrome, Adrenal Insufficiency, Salivary cortisol, Salivary cortisone, Reference intervals, Diagnostic accuracy, Error sources
Nationell ämneskategori
Endokrinologi och diabetes
Forskningsämne
invärtesmedicin; medicinsk biokemi
Identifikatorer
urn:nbn:se:umu:diva-208137 (URN)978-91-8070-045-0 (ISBN)978-91-8070-046-7 (ISBN)
Disputation
2023-06-09, Lärosal A, målpunkt T9, Norrlands universitetssjukhus, Daniel Naezéns väg, Umeå, 09:00 (Svenska)
Opponent
Handledare
Forskningsfinansiär
Region VästerbottenUmeå universitet, 370549500
Tillgänglig från: 2023-05-17 Skapad: 2023-05-11 Senast uppdaterad: 2024-03-25Bibliografiskt granskad

Open Access i DiVA

fulltext(1671 kB)237 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1671 kBChecksumma SHA-512
b4db723ea7251a67e889c86db0a2dca5e4a27181350a97896e0976cd568361cfdc402aa213269dd52f237a0bfa21fef9f6cfc920f3a051fc85d171ea86e3f061
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Bäcklund, NilsBrattsand, GöranLundstedt, StaffanOlsson, TommyDahlqvist, Per

Sök vidare i DiVA

Av författaren/redaktören
Bäcklund, NilsBrattsand, GöranLundstedt, StaffanOlsson, TommyDahlqvist, Per
Av organisationen
Institutionen för folkhälsa och klinisk medicinKlinisk kemi
I samma tidskrift
Clinical Chemistry and Laboratory Medicine
Analytisk kemiEndokrinologi och diabetes

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 239 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 695 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf