Umeå universitets logga

umu.sePublikationer
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Spatially repeatable components from ultrafast ultrasound are associated with motor unit activity in human isometric contractions
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Department of Biomedical Engineering, Lund University, Lund, Sweden.ORCID-id: 0000-0003-4328-5467
Laboratory for Engineering of the Neuromuscular System (LISiN), Department of Electronics and Telecommunication, Politecnico di Torino, Turin, Italy; PoliToBIOMed Lab, Politecnico di Torino, Turin, Italy.ORCID-id: 0000-0002-0877-7960
Laboratory for Engineering of the Neuromuscular System (LISiN), Department of Electronics and Telecommunication, Politecnico di Torino, Turin, Italy; PoliToBIOMed Lab, Politecnico di Torino, Turin, Italy.ORCID-id: 0000-0002-5295-5314
PoliToBIOMed Lab, Politecnico di Torino, Turin, Italy; Biolab, Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Journal of Neural Engineering, ISSN 1741-2560, E-ISSN 1741-2552, Vol. 20, nr 4, s. 046016-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: Ultrafast ultrasound (UUS) imaging has been used to detect intramuscular mechanical dynamics associated with single motor units (MUs). Detecting MUs from ultrasound sequences requires decomposing a velocity field into components, each consisting of an image and a signal. These components can be associated with putative MU activity or spurious movements (noise). The differentiation between putative MUs and noise has been accomplished by comparing the signals with MU firings obtained from needle electromyography (EMG). Here, we examined whether the repeatability of the images over brief time intervals can serve as a criterion for distinguishing putative MUs from noise in low-force isometric contractions.

Approach: UUS images and high-density surface EMG (HDsEMG) were recorded simultaneously from 99 MUs in the biceps brachii of five healthy subjects. The MUs identified through HDsEMG decomposition were used as a reference to assess the outcomes of the ultrasound-based components. For each contraction, velocity sequences from the same eight-second ultrasound recording were separated into consecutive two-second epochs and decomposed. To evaluate the repeatability of components' images across epochs, we calculated the Jaccard Similarity Coefficient (JSC). JSC compares the similarity between two images providing values between 0 and 1. Finally, the association between the components and the MUs from HDsEMG was assessed.

Main results: All the MU-matched components had JSC>0.38, indicating they were repeatable and accounted for about one-third of the HDsEMG-detected MUs (1.8±1.6 matches over 4.9±1.8 MUs). The repeatable components (JSC>0.38) represented 14% of the total components (6.5±3.3 components). These findings align with our hypothesis that intra-sequence repeatability can differentiate putative MUs from noise and can be used for data reduction.

Significance: This study provides the foundation for developing stand-alone methods to identify MU in UUS sequences and towards real-time imaging of MUs. These methods are relevant for studying muscle neuromechanics and designing novel neural interfaces.

Ort, förlag, år, upplaga, sidor
Institute of Physics (IOP), 2023. Vol. 20, nr 4, s. 046016-
Nationell ämneskategori
Fysiologi och anatomi Medicinsk bildvetenskap
Identifikatorer
URN: urn:nbn:se:umu:diva-212028DOI: 10.1088/1741-2552/ace6fcISI: 001036280900001PubMedID: 37437598Scopus ID: 2-s2.0-85166226839OAI: oai:DiVA.org:umu-212028DiVA, id: diva2:1782480
Forskningsfinansiär
Vetenskapsrådet, 2022-04747Centrum för Idrottsforskning, D2023-0003Tillgänglig från: 2023-07-14 Skapad: 2023-07-14 Senast uppdaterad: 2025-02-10Bibliografiskt granskad

Open Access i DiVA

fulltext(4692 kB)204 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 4692 kBChecksumma SHA-512
e57be6988403ffba37d694fef11ce9898ba20a8959eef6cf1ec2c996773cab9c81467a9af832cfef666887ef4157e5941671846c860067d04d18fc5f2582797a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Rohlén, RobinGrönlund, Christer

Sök vidare i DiVA

Av författaren/redaktören
Rohlén, RobinCarbonaro, MarcoCerone, Giacinto LuigiGrönlund, Christer
Av organisationen
Radiofysik
I samma tidskrift
Journal of Neural Engineering
Fysiologi och anatomiMedicinsk bildvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 212 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 539 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf