Simultaneous Recording of ICG and ECG Using Z-RPI Device with Minimum Number of Electrodes
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria.ORCID-id: 0000-0001-6640-1868
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria.
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria.
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Journal of Sensors, ISSN 1687-725X, E-ISSN 1687-7268, Vol. 2018, artikel-id 3269534Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Impedance cardiography (ICG) is a noninvasive method for monitoring mechanical function of the heart with the use of electrical bioimpedance measurements. This paper presents the feasibility of recording an ICG signal simultaneously with electrocardiogram signal (ECG) using the same electrodes for both measurements, for a total of five electrodes rather than eight electrodes. The device used is the Z-RPI. The results present good performance and show waveforms presenting high similarity with the different signals reported using different electrodes for acquisition; the heart rate values were calculated and they present accurate evaluation between the ECG and ICG heart rates. The hemodynamics and cardiac parameter results present similitude with the physiological parameters for healthy people reported in the literature. The possibility of reducing number of electrodes used for ICG measurement is an encouraging step to enabling wearable and personal health monitoring solutions.

Ort, förlag, år, upplaga, sidor
Hindawi Publishing Corporation, 2018. Vol. 2018, artikel-id 3269534
Nationell ämneskategori
Annan teknik
Identifikatorer
URN: urn:nbn:se:umu:diva-213086DOI: 10.1155/2018/3269534ISI: 000453004900001Scopus ID: 2-s2.0-85062625652OAI: oai:DiVA.org:umu-213086DiVA, id: diva2:1789823
Tillgänglig från: 2023-08-21 Skapad: 2023-08-21 Senast uppdaterad: 2023-08-24Bibliografiskt granskad

Open Access i DiVA

fulltext(3495 kB)32 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3495 kBChecksumma SHA-512
28852540d42a0ba55827b8c9d6054b4494445008281daba0c26703fae6500ffa5c3f633abdf6d7612da640743485d6be5ff600fd056e947ff71cbd3d2d0de9f1
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Benouar, Sara

Sök vidare i DiVA

Av författaren/redaktören
Hafid, AbdelakramBenouar, Sara
I samma tidskrift
Journal of Sensors
Annan teknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 37 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 97 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf