Region of interest focused MRI to synthetic CT translation using regression and segmentation multi-task network
GE Healthcare, Munich, Germany; Department of Quantitative Biomedicine, University of Zurich, Zurich, Switzerland.
Umeå University, Faculty of Medicine, Department of Radiation Sciences.ORCID iD: 0000-0001-7539-2262
GE Healthcare, Munich, Germany.
GE Healthcare, Bangalore, India.
Show others and affiliations
2023 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 68, no 19, article id 195003Article in journal (Refereed) Published
Abstract [en]

Objective: In MR-only clinical workflow, replacing CT with MR image is of advantage for workflow efficiency and reduces radiation to the patient. An important step required to eliminate CT scan from the workflow is to generate the information provided by CT via an MR image. In this work, we aim to demonstrate a method to generate accurate synthetic CT (sCT) from an MR image to suit the radiation therapy (RT) treatment planning workflow. We show the feasibility of the method and make way for a broader clinical evaluation.

Approach: We present a machine learning method for sCT generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. The misestimation of bone density in the radiation path could lead to unintended dose delivery to the target volume and results in suboptimal treatment outcome. We propose a loss function that favors a spatially sparse bone region in the image. We harness the ability of the multi-task network to produce correlated outputs as a framework to enable localization of region of interest (RoI) via segmentation, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task.

Main results: We have included 54 brain patient images in this study and tested the sCT images against reference CT on a subset of 20 cases. A pilot dose evaluation was performed on 9 of the 20 test cases to demonstrate the viability of the generated sCT in RT planning. The average quantitative metrics produced by the proposed method over the test set were-(a) mean absolute error (MAE) of 70 ± 8.6 HU; (b) peak signal-to-noise ratio (PSNR) of 29.4 ± 2.8 dB; structural similarity metric (SSIM) of 0.95 ± 0.02; and (d) Dice coefficient of the body region of 0.984 ± 0.

Significance: We demonstrate that the proposed method generates sCT images that resemble visual characteristics of a real CT image and has a quantitative accuracy that suits RT dose planning application. We compare the dose calculation from the proposed sCT and the real CT in a radiation therapy treatment planning setup and show that sCT based planning falls within 0.5% target dose error. The method presented here with an initial dose evaluation makes an encouraging precursor to a broader clinical evaluation of sCT based RT planning on different anatomical regions.

Place, publisher, year, edition, pages
Institute of Physics (IOP), 2023. Vol. 68, no 19, article id 195003
Keywords [en]
focused loss, image translation, MRI radiation therapy, multi-task CNN, synthetic CT
National Category
Radiology, Nuclear Medicine and Medical Imaging Medical Imaging
Identifiers
URN: urn:nbn:se:umu:diva-214754DOI: 10.1088/1361-6560/acefa3ISI: 001144993400001PubMedID: 37567235Scopus ID: 2-s2.0-85171601230OAI: oai:DiVA.org:umu-214754DiVA, id: diva2:1804589
Funder
EU, Horizon 2020Available from: 2023-10-13 Created: 2023-10-13 Last updated: 2025-04-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Bylund, MikaelJonsson, JoakimNyholm, Tufve

Search in DiVA

By author/editor
Bylund, MikaelJonsson, JoakimNyholm, Tufve
By organisation
Department of Radiation Sciences
In the same journal
Physics in Medicine and Biology
Radiology, Nuclear Medicine and Medical ImagingMedical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 227 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf