Reagentless impedimetric immunosensor for monitoring of methotrexate in human blood serum using multiwalled carbon nanotube@polypyrrole/polytyramine film electrode
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Department of Chemistry, University of Prishtina, Prishtina, Republic of Kosovo.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. Industrial Chemistry and Reaction Engineering, Johan Gadolin Process Chemistry Centre, Åbo Akademi University, Åbo-Turku, Finland.
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 268, nr Part 1, artikel-id 125316Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Ensuring effective monitoring of methotrexate (MTX) levels in the bloodstream of cancer patients undergoing high-dose methotrexate chemotherapy is crucial to prevent potentially harmful side effects. However, the absence of portable analytical devices suitable for point-of-care bedside monitoring has presented a significant obstacle to achieving real-time MTX monitoring. In this study, we developed an impedimetric immunosensor that doesn't require reagents for measuring MTX levels in undiluted human blood serum. This reagentless approach simplifies the assay process, enabling rapid and straightforward MTX quantification. The immunosensor transducer was fabricated by electrodepositing conductive network of porous multiwalled carbon nanotube@polypyrrole/polytyramine on screen-printed gold microchip electrode (SP–Au/MWCNT70@PPy-PTA). Polyclonal anti-MTX antibodies were immobilized on the film, acting as the immunorecognition element. Non-specific binding was prevented by blocking the transducer interface with denatured bovine serum albumin (dBSA) fibrils, resulting in SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA film electrode. When MTX binds to the SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA interface, the film conductance and electron transfer resistance changes. This conductivity attenuation allows for electrochemical impedimetric signal transduction without a redox-probe solution. The electrochemical impedance spectroscopy (EIS) results showed increased charge transfer resistance and phase angle as MTX concentrations increased. The SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA demonstrated high sensitivity, with a linear response from 0.02 to 20.0 μM and a detection limit of 1.93 nM. The detection limit was 50 times lower than the intended safe level of MTX in human serum. The immunosensor exhibited minimal cross-reactivity with endogenous MTX analogs and serum proteins. The SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA immunosensor presents a simple and rapid method for therapeutic drug monitoring compared to traditional immunoassay systems.

Ort, förlag, år, upplaga, sidor
Elsevier, 2024. Vol. 268, nr Part 1, artikel-id 125316
Nyckelord [en]
Therapeutic drug monitoring, Methotrexate, Reagentless sensor, Electrochemical impedance spectroscopy, Carbon nanotube network
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:umu:diva-215536DOI: 10.1016/j.talanta.2023.125316ISI: 001101380100001Scopus ID: 2-s2.0-85174487495OAI: oai:DiVA.org:umu-215536DiVA, id: diva2:1806372
Forskningsfinansiär
KempestiftelsernaTillgänglig från: 2023-10-20 Skapad: 2023-10-20 Senast uppdaterad: 2025-04-24Bibliografiskt granskad

Open Access i DiVA

fulltext(8130 kB)144 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 8130 kBChecksumma SHA-512
96a5a5fad8e3e590b20e82c2e9074a2060ddfc683e0222da16888a2c916991eb4bb0c4b7b2dedb6721cd98783bd8352e6e1b89250d855cc2ac57ae5c32abf5cf
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Adeniyi, OmotayoOsmanaj, BlerinaManavalan, GopinathanMikkola, Jyri-PekkaTesfalidet, Solomon

Sök vidare i DiVA

Av författaren/redaktören
Adeniyi, OmotayoOsmanaj, BlerinaManavalan, GopinathanMikkola, Jyri-PekkaTesfalidet, Solomon
Av organisationen
Kemiska institutionen
I samma tidskrift
Talanta: The International Journal of Pure and Applied Analytical Chemistry
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 145 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 459 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf