Electrochemically modified poly(dicyandiamide) electrodes for detecting hydrazine in neutral pHVisa övriga samt affilieringar
2023 (Engelska)Ingår i: Industrial & Engineering Chemistry Research, ISSN 0888-5885, E-ISSN 1520-5045, Vol. 62, nr 44, s. 18271-18279Artikel i tidskrift (Refereegranskat) Published
Abstract [en]
A new technique for sensing nanomolar concentrations of hydrazine in water samples is reported. A screen-printed carbon electrode (SPCE) altered using an amine-azo functional group encompassing poly(dicyandiamide) is used in this study. The modified electrode exhibits an enhanced activity toward hydrazine detection at a lower overpotential and broad linear scale between 20 nM and 1 mM, with an accurate sensitivity value of 0.1 nA μm–1 cm–2. To the best of our knowledge, poly(dicyandiamide)-modified electrodes exhibit one of the lowest limits of detection for any metal-free electrode that detects 6.7 nM (S/N = 3) of hydrazine. The method established sufficient selectivity and better recoveries. Finally, the poly(dicyandiamide)-modified SPCE* is highly suitable for electrochemical determination of hydrazine in water samples from tap and lake.
Ort, förlag, år, upplaga, sidor
American Chemical Society (ACS), 2023. Vol. 62, nr 44, s. 18271-18279
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:umu:diva-216247DOI: 10.1021/acs.iecr.3c02669ISI: 001102285700001Scopus ID: 2-s2.0-85177814574OAI: oai:DiVA.org:umu-216247DiVA, id: diva2:1809974
2023-11-062023-11-062023-12-14Bibliografiskt granskad