Umeå University's logo

umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Accurate identification of motoneuron discharges from ultrasound images across the full muscle cross-section
Department of Bioengineering, Imperial College, London, United Kingdom.
Department of Biomedical Engineering, Lund University, Sweden .ORCID iD: 0000-0003-4328-5467
Department of Bioengineering, Imperial College, London, United Kingdom.
Department of Bioengineering, Imperial College, London, United Kingdom.
Show others and affiliations
2024 (English)In: IEEE Transactions on Biomedical Engineering, ISSN 0018-9294, E-ISSN 1558-2531, Vol. 71, no 5, p. 1466-1477Article in journal (Refereed) Epub ahead of print
Abstract [en]

Objective: Non-invasive identification of motoneuron (MN) activity commonly uses electromyography (EMG). However, surface EMG (sEMG) detects only superficial sources, at less than approximately 10-mm depth. Intramuscular EMG can detect deep sources, but it is limited to sources within a few mm of the detection site. Conversely, ultrasound (US) images have high spatial resolution across the whole muscle cross-section. The activity of MNs can be extracted from US images due to the movements that MN activation generates in the innervated muscle fibers. Current US-based decomposition methods can accurately identify the location and average twitch induced by MN activity. However, they cannot accurately detect MN discharge times.

Methods: Here, we present a method based on the convolutive blind source separation of US images to estimate MN discharge times with high accuracy. The method was validated across 10 participants using concomitant sEMG decomposition as the ground truth.

Results: 140 unique MN spike trains were identified from US images, with a rate of agreement (RoA) with sEMG decomposition of 87.4 ± 10.3%. Over 50% of these MN spike trains had a RoA greater than 90%. Furthermore, with US, we identified additional MUs well beyond the sEMG detection volume, at up to >30 mm below the skin.

Conclusion: The proposed method can identify discharges of MNs innervating muscle fibers in a large range of depths within the muscle from US images. Significance: The proposed methodology can non-invasively interface with the outer layers of the central nervous system innervating muscles across the full cross-section.

Place, publisher, year, edition, pages
IEEE, 2024. Vol. 71, no 5, p. 1466-1477
National Category
Medical Imaging Physiology and Anatomy
Identifiers
URN: urn:nbn:se:umu:diva-217558DOI: 10.1109/TBME.2023.3340019OAI: oai:DiVA.org:umu-217558DiVA, id: diva2:1817802
Funder
EU, Horizon 2020, 899822The Swedish Brain Foundation, PS2022-0021Available from: 2023-12-07 Created: 2023-12-07 Last updated: 2025-02-10

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Rohlén, Robin

Search in DiVA

By author/editor
Rohlén, Robin
In the same journal
IEEE Transactions on Biomedical Engineering
Medical ImagingPhysiology and Anatomy

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 175 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf