Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Altered probe pressure and body position increase diagnostic accuracy for men and women in detecting hepatic steatosis using quantitative ultrasound
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Department of Radiology in Östersund, Östersund, Sweden; Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.ORCID-id: 0000-0001-9338-1639
Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden; Department of Radiology in Linköping, Linköping, Sweden.ORCID-id: 0000-0003-3124-8044
Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden; Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.ORCID-id: 0000-0002-2928-4188
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.ORCID-id: 0000-0003-4288-1208
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 34, nr 9, s. 5989-5999Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: To evaluate the diagnostic performance of ultrasound guided attenuation parameter (UGAP) for evaluating liver fat content with different probe forces and body positions, in relation to sex, and compared with proton density fat fraction (PDFF).

Methods: We prospectively enrolled a metabolic dysfunction-associated steatotic liver disease (MASLD) cohort that underwent UGAP and PDFF in the autumn of 2022. Mean UGAP values were obtained in supine and 30° left decubitus body position with normal 4 N and increased 30 N probe force. The diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUC).

Results: Among 60 individuals (mean age 52.9 years, SD 12.9; 30 men), we found the best diagnostic performance with increased probe force in 30° left decubitus position (AUC 0.90; 95% CI 0.82–0.98) with a cut-off of 0.58 dB/cm/MHz. For men, the best performance was in supine (AUC 0.91; 95% CI 0.81–1.00) with a cut-off of 0.60 dB/cm/MHz, and for women, 30° left decubitus position (AUC 0.93; 95% CI 0.83–1.00), with a cut-off 0.56 dB/cm/MHz, and increased 30 N probe force for both genders. No difference was in the mean UGAP value when altering body position. UGAP showed good to excellent intra-reproducibility (Intra-class correlation 0.872; 95% CI 0.794–0.921).

Conclusion: UGAP provides excellent diagnostic performance to detect liver fat content in metabolic dysfunction-associated steatotic liver diseases, with good to excellent intra-reproducibility. Regardless of sex, the highest diagnostic accuracy is achieved with increased probe force with men in supine and women in 30° left decubitus position, yielding different cut-offs.

Clinical relevance statement: The ultrasound method ultrasound-guided attenuation parameter shows excellent diagnostic accuracy and performs with good to excellent reproducibility. There is a possibility to alter body position and increase probe pressure, and different performances for men and women should be considered for the highest accuracy.

Ort, förlag, år, upplaga, sidor
Springer Nature, 2024. Vol. 34, nr 9, s. 5989-5999
Nationell ämneskategori
Klinisk medicin
Identifikatorer
URN: urn:nbn:se:umu:diva-222436DOI: 10.1007/s00330-024-10655-1ISI: 001177772800001PubMedID: 38459346Scopus ID: 2-s2.0-85202776922OAI: oai:DiVA.org:umu-222436DiVA, id: diva2:1845160
Forskningsfinansiär
Forskningsrådet i Sydöstra Sverige, FORSS, 752871Region Jämtland HärjedalenLinköpings universitetLions Cancerforskningsfond i Norr, 20-2221Tillgänglig från: 2024-03-18 Skapad: 2024-03-18 Senast uppdaterad: 2024-10-23Bibliografiskt granskad

Open Access i DiVA

fulltext(1598 kB)42 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 1598 kBChecksumma SHA-512
f482b6a6a65f007d512a4b809ce7b090ae9d00869d9b3fb6f2587abc9bd465b01a3725eb64ed4e4962436717b1576ee44ee2fc6715f5f73273403411b3a8ba65
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Byenfeldt, MarieGrönlund, ChristerLindam, Anna

Sök vidare i DiVA

Av författaren/redaktören
Byenfeldt, MarieKihlberg, JohanNasr, PatrikGrönlund, ChristerLindam, AnnaBartholomä, Wolf CLundberg, PeterEkstedt, Mattias
Av organisationen
Institutionen för strålningsvetenskaperAllmänmedicin
I samma tidskrift
European Radiology
Klinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 103 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 329 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf