Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Accuracy and reliability for estimating jaw functional range of motion
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
Umeå universitet, Medicinska fakulteten, Institutionen för diagnostik och intervention.ORCID-id: 0000-0003-1635-122x
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.ORCID-id: 0000-0002-8986-9401
2024 (Engelska)Ingår i: Gait & Posture, ISSN 0966-6362, E-ISSN 1879-2219, Vol. 113, s. 280-286Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Three dimensional (3D) kinematic analysis based on motion capture can study synchronized data from the integrated jaw and neck motor system. Jaw function is commonly estimated on linear outcome variables of motion range. By combining jaw border movements in three planes the functional range of motion could be described by movement area and volume measures.

Research question: Can we ensure the accuracy, test-retest reliability, and intra-individual variability with 3D kinematic analysis for estimating jaw functional range of motion (ROM), including jaw movement area and volume and jaw and head linear measures?

Methods: Accuracy was estimated by applying the method to a set of beakers with known volume, based on the percentage deviation and Pearson correlation coefficient between target and estimated values. Test-retest reliability was then analysed on maximum jaw movements performed in a pre-determined movement sequence by 17 pain-free participants (25.4 years ± 2.4) to estimate jaw functional ROM. Intraclass correlation coefficients (ICC) were calculated, and Bland-Altman plots were constructed. Coefficient of variation (CV) tested the within session reliability.

Results: The accuracy in volume and area measurements were high with a percentage deviation (0.03±0.59) and (1.2±0.45), respectively, with a strong linear relationship (R2=0.99) between target and estimated values. The test-retest reliability showed moderate to excellent reliability, and Bland-Altman plots showed good agreement. Overall, CVs showed high repeatability, but jaw movements in horizontal directions were less reliable and presented higher variability.

Significance: The study with 3D kinematic analysis of jaw functional ROM, provides a methodological basis for accurate and reliable measurements. The study presents a new way to estimate jaw functional ROM measures, useful for evaluation in clinical intervention, for instance in pain and jaw dysfunction. Moreover, the natural biological movement variability and the complexity of the interplay of jaw-head movement will be emphasised.

Ort, förlag, år, upplaga, sidor
Elsevier, 2024. Vol. 113, s. 280-286
Nyckelord [en]
Accuracy, Head, Jaw, Kinematics, Reliability
Nationell ämneskategori
Fysioterapi
Identifikatorer
URN: urn:nbn:se:umu:diva-227927DOI: 10.1016/j.gaitpost.2024.06.017ISI: 001267406300001PubMedID: 38970930Scopus ID: 2-s2.0-85197532941OAI: oai:DiVA.org:umu-227927DiVA, id: diva2:1884822
Forskningsfinansiär
Region Västerbotten, 7004250Tillgänglig från: 2024-07-18 Skapad: 2024-07-18 Senast uppdaterad: 2025-04-24Bibliografiskt granskad

Open Access i DiVA

fulltext(1793 kB)104 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1793 kBChecksumma SHA-512
698cf592ae327c8e757c07af9396dfa35265b9e80ca4c642a3b2ef4434dc22b599a25c3b13ef43c183124bfeb043a90dc6d90372a095c0970c5365c412566fb4
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Nilsson, EvelinaGrip, HelenaÖsterlund, Catharina

Sök vidare i DiVA

Av författaren/redaktören
Nilsson, EvelinaGrip, HelenaÖsterlund, Catharina
Av organisationen
Institutionen för odontologiInstitutionen för diagnostik och intervention
I samma tidskrift
Gait & Posture
Fysioterapi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 104 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 295 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf