Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Practical issues in assessing nailfold capillaroscopic images: a summary
School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
Medical Image and Signal Processing Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.ORCID-id: 0000-0002-7309-1105
Rheumatology Section, Department of Internal Medicine, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Clinical Rheumatology, ISSN 0770-3198, E-ISSN 1434-9949, Vol. 38, nr 9, s. 2343-2354Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Nailfold capillaroscopy (NC) is a highly sensitive, safe, and non-invasive technique to assess involvement rate of microvascularity in dermatomyositis and systemic sclerosis. A large number of studies have focused on NC pattern description, classification, and scoring system validation, but minimal information has been published on the accuracy and precision of the measurement. The objective of this review article is to identify different factors affecting the reliability and validity of the assessment in NC. Several factors can affect the reliability of the examination, e.g., physiological artifacts, the nailfold imaging instrument, human factors, and the assessment rules and standards. It is impossible to avoid all artifacts, e.g., skin transparency, physically injured fingers, and skin pigmentation. However, minimization of the impact of some of these artifacts by considering some protocols before the examination and by using specialized tools, training, guidelines, and software can help to reduce errors in the measurement and assessment of NC images. Establishing guidelines and instructions for automatic characterization and measurement based on machine learning techniques also may reduce ambiguities and the assessment time.

Ort, förlag, år, upplaga, sidor
Springer, 2019. Vol. 38, nr 9, s. 2343-2354
Nyckelord [en]
Assessment, Measurement, Nailfold capillaroscopy
Nationell ämneskategori
Klinisk medicin
Identifikatorer
URN: urn:nbn:se:umu:diva-229455DOI: 10.1007/s10067-019-04644-9ISI: 000483770400007PubMedID: 31278512Scopus ID: 2-s2.0-85068831307OAI: oai:DiVA.org:umu-229455DiVA, id: diva2:1896330
Tillgänglig från: 2024-09-10 Skapad: 2024-09-10 Senast uppdaterad: 2024-09-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Karbalaie, Abdolamir

Sök vidare i DiVA

Av författaren/redaktören
Karbalaie, AbdolamirEmrani, Zahra
I samma tidskrift
Clinical Rheumatology
Klinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 60 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf