Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Deep learning estimation of proton stopping power with photon-counting computed tomography: a virtual study
KTH Royal Institute of Technology, Stockholm, Sweden; Karolinska University Hospital, Stockholm, Sweden.
KTH Royal Institute of Technology, Stockholm, Sweden; Karolinska University Hospital, Stockholm, Sweden.
KTH Royal Institute of Technology, Stockholm, Sweden; Karolinska University Hospital, Stockholm, Sweden.
GE HealthCare, Stockholm, Sweden.
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Journal of Medical Imaging, ISSN 2329-4302, E-ISSN 2329-4310, Vol. 11, nr S1, artikel-id S12809Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: Proton radiation therapy may achieve precise dose delivery to the tumor while sparing non-cancerous surrounding tissue, owing to the distinct Bragg peaks of protons. Aligning the high-dose region with the tumor requires accurate estimates of the proton stopping power ratio (SPR) of patient tissues, commonly derived from computed tomography (CT) image data. Photon-counting detectors for CT have demonstrated advantages over their energy-integrating counterparts, such as improved quantitative imaging, higher spatial resolution, and filtering of electronic noise. We assessed the potential of photon-counting computed tomography (PCCT) for improving SPR estimation by training a deep neural network on a domain transform from PCCT images to SPR maps.

Approach: The XCAT phantom was used to simulate PCCT images of the head with CatSim, as well as to compute corresponding ground truth SPR maps. The tube current was set to 260 mA, tube voltage to 120 kV, and number of view angles to 4000. The CT images and SPR maps were used as input and labels for training a U-Net.

Results: Prediction of SPR with the network yielded average root mean square errors (RMSE) of 0.26% to 0.41%, which was an improvement on the RMSE for methods based on physical modeling developed for single-energy CT at 0.40% to 1.30% and dual-energy CT at 0.41% to 3.00%, performed on the simulated PCCT data.

Conclusions: These early results show promise for using a combination of PCCT and deep learning for estimating SPR, which in extension demonstrates potential for reducing the beam range uncertainty in proton therapy.

Ort, förlag, år, upplaga, sidor
SPIE - The International Society for Optics and Photonics, 2024. Vol. 11, nr S1, artikel-id S12809
Nyckelord [en]
photon-counting computed tomography, proton therapy, proton stopping power, deep learning
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-233224DOI: 10.1117/1.jmi.11.s1.s12809ISI: 001386330400005PubMedID: 39574807Scopus ID: 2-s2.0-85214080434OAI: oai:DiVA.org:umu-233224DiVA, id: diva2:1923717
Forskningsfinansiär
Vetenskapsrådet, 2021-05103Stiftelsen för strategisk forskning (SSF), APR20-0012CancerfondenTillgänglig från: 2024-12-30 Skapad: 2024-12-30 Senast uppdaterad: 2025-01-13Bibliografiskt granskad

Open Access i DiVA

fulltext(4207 kB)122 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 4207 kBChecksumma SHA-512
6b54fe9e35a4d5299fc8e600386e9d8458a278fdc4240e41effccdb527e48fbfcd9e67fce1bb561ba77b644baf1a50cdb832771c75144521998cc515e3e1d6fd
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Andersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Jonas
Av organisationen
Institutionen för diagnostik och intervention
I samma tidskrift
Journal of Medical Imaging
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 122 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 438 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf