Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Cone beam computed tomography: Frequency and exposure settings at University (Dental) hospitals in Central and Northern Europe
Universität Bern, Division of Oral Diagnostic Sciences, School of Dental Medicine, Freiburgstr. 7, Bern, Switzerland.
Private Dental Office, St Gallen, Switzerland.
Universität Bern, Department of Oral Surgery and Stomotology, Switzerland.
Aarhus University, Department of Dentistry and Oral Health - Section for Oral Radiology and Endodontics, Denmark.
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: European Journal of Radiology, ISSN 0720-048X, E-ISSN 1872-7727, Vol. 183, artikel-id 111886Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To investigate the frequency of CBCT scans, the exposure settings, volume sizes and the patient demographics (age and sex) of patients undergoing CBCT scans in university-based dental hospitals in different European countries over a one-year period.

Method: Eight University Dental Hospitals from eight countries in central and northern Europe agreed to collect data from their CBCT-databases. Exposure data including field of view (FOV), dose area product (DAP) and optimization settings plus (anonymous) age and sex of the patients were collected for the entire year 2023. In addition, centre- and healthcare-system- related characteristics were assembled. Data were statistically evaluated using R Statistical Software.

Results: A total of 7320 CBCT-scans from eight centres and eight different CBCT-machines were evaluated. DAPs ranged between 34 and 4390 mGycm2 (mean: 700.8 mGycm2), kV between 60 kV and 120 kV. Patient age (range 4 yrs to 97 yrs) differed significantly between the centres, yet with a cumulative peak between 10 and 20 yrs. Optimization protocols were observed for all centres, depending on their centre- and also healthcare-characteristics. 21 % of the scans applied some sort of special dose reduction means.

Conclusions: The overall age-peak between 10 and 20 yrs highlights the need to optimized maxillofacial CBCT-protocols. The differences between the centres seem to be mainly related to healthcare-system and centre-related characteristics, which differ largely between the eight centres.

Ort, förlag, år, upplaga, sidor
Elsevier, 2025. Vol. 183, artikel-id 111886
Nationell ämneskategori
Odontologi Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-233378DOI: 10.1016/j.ejrad.2024.111886ISI: 001391906300001Scopus ID: 2-s2.0-85212570430OAI: oai:DiVA.org:umu-233378DiVA, id: diva2:1925896
Tillgänglig från: 2025-01-09 Skapad: 2025-01-09 Senast uppdaterad: 2025-04-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Levring Jäghagen, Eva

Sök vidare i DiVA

Av författaren/redaktören
Levring Jäghagen, Eva
Av organisationen
Institutionen för odontologi
I samma tidskrift
European Journal of Radiology
OdontologiRadiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 106 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf