Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Detection of unlabeled polystyrene micro- and nanoplastics in mammalian tissue by optical photothermal infrared spectroscopy
RECENDT GmbH─Research Center for Non-Destructive Testing, Linz, Upper Austria, Austria; CBmed GmbH─Center for Biomarker Research in Medicine, Graz, Styria, Austria.
CBmed GmbH─Center for Biomarker Research in Medicine, Graz, Styria, Austria; Department of Pharmaceutical Sciences, Division of Pharmaceutical Chemistry, University Vienna, Vienna, Austria.
CBmed GmbH─Center for Biomarker Research in Medicine, Graz, Styria, Austria; Clinical Institute of Pathology, Department for Experimental and Laboratory Animal Pathology, Medical University of Vienna, Vienna, Austria; Comprehensive Cancer Center, Medical University Vienna, Vienna, Austria; Department for Radiation Oncology, Medical University of Vienna, Vienna, Austria.
CBmed GmbH─Center for Biomarker Research in Medicine, Graz, Styria, Austria.
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: Analytical Chemistry, ISSN 0003-2700, E-ISSN 1520-6882, Vol. 97, nr 31, s. 16714-16722Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this study, we investigate the efficacy of optical photothermal infrared (O-PTIR) spectroscopy, also known as mid-infrared photothermal (MIP) microscopy, for label-free and nondestructive detection of micro- and nanoplastics (MNPs) down to diameters of 200 nm in mammalian tissues. Experiments with both in vitro three-dimensional cell cultures derived from HTC116 colorectal cancer cell line and in vivo mouse tissue models were conducted. Spherical polystyrene particles served as reliable model systems for evaluating spatial resolution limits and quality of spectra. Our findings demonstrate the superior resolution of O-PTIR in imaging individual particles of 200 nm in mouse kidney tissues, surpassing the capabilities of traditional Fourier transform infrared (FTIR) spectroscopy. Furthermore, we apply a semiautomated image analysis that incorporates machine learning algorithms to accelerate the detection process, thus improving throughput and minimizing the potential for human error. The results confirm that O-PTIR is able to provide high-quality, artifact-free spectral images in a contact-less manner and significantly outperforms traditional infrared spectroscopy in terms of spatial resolution and signal-to-noise ratio in complex biological matrices.

Ort, förlag, år, upplaga, sidor
American Chemical Society (ACS), 2025. Vol. 97, nr 31, s. 16714-16722
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:umu:diva-243641DOI: 10.1021/acs.analchem.4c05400ISI: 001542697900001PubMedID: 40749980Scopus ID: 2-s2.0-105013667301OAI: oai:DiVA.org:umu-243641DiVA, id: diva2:1993131
Forskningsfinansiär
EU, Horisont 2020, 675712EU, Horisont 2020, P101072735EU, Horisont 2020, 101119427Tillgänglig från: 2025-08-29 Skapad: 2025-08-29 Senast uppdaterad: 2025-08-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Kenner, Lukas

Sök vidare i DiVA

Av författaren/redaktören
Kenner, Lukas
Av organisationen
Institutionen för molekylärbiologi (Medicinska fakulteten)
I samma tidskrift
Analytical Chemistry
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 30 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf