Umeå universitets logga

umu.sePublikationer
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A comparative study between ultrasound-guided-attenuation-parameter (UGAP), controlled attenuation parameter (CAP), and proton density fat fraction (PDFF) for assessment of hepatic steatosis
Clinical Department of Radiology in Östersund, Region Jämtland and Härjedalen, Östersund, Sweden; Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medicine Imaging and Visualization Science (CMIV), Linköping University, Linköping, Sweden.
Umeå universitet, Medicinska fakulteten, Institutionen för diagnostik och intervention.ORCID-id: 0000-0003-4288-1208
Center for Medicine Imaging and Visualization Science (CMIV), Linköping University, Linköping, Sweden; Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin.ORCID-id: 0000-0002-6230-0354
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Scandinavian Journal of Gastroenterology, ISSN 0036-5521, E-ISSN 1502-7708, Vol. 61, nr 1, s. 124-132Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: Gastroenterology clinics often assess hepatic steatosis using CAP-FibroScan, while radiology departments increasingly apply UGAP instead of subjective B-mode ultrasound. This study compares CAP and UGAP feasibility and diagnostic performance across steatosis stages, using PDFF as reference.

Materials and methods: Healthy controls and a cohort with known steatosis and fibrosis were examined between September 2022 and October 2024. Presence of steatosis (≥S1) defined as ≥5% PDFF, and presence of fibrosis was evaluated with MRE. Participants with even sex distribution were examined in supine and 30° left decubitus position; for UGAP, with normal (4 N) and (30 N) probe force. Diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUROC).

Results: In the group of N = 97 CAP demonstrated 91% feasibility in supine and 80% in lateral position. UGAP showed 100% feasibility for all examination techniques. The whole group was divided according to steatosis stages of PDFF. When differentiating ≥ S1, CAP supine accuracy was AUC 0.81 (95%CI: 0.71–0.92), and UGAP supine/30N accuracy was 0.88 (95%CI: 0.88–0.95). Differentiating S0 and S1 vs. S2 and S3, the CAP AUC was 0.81 (95% CI: 0.72–0.90), and the UGAP supine/30 N AUC was 0.93 (95%CI: 0.88–0.99). When differentiating S0, S1, and S2 vs. S3, the CAP AUC was 0.90 (95%CI: 0.83–0.97), and the UGAP supine/4N AUC was 0.97 (95%CI: 0.94–1.00). UGAP increased performance in both sexes using increased probe force.

Conclusions: UGAP provides absolute feasibility and higher diagnostic performance. CAP should not be performed in left position.

Ort, förlag, år, upplaga, sidor
Taylor & Francis, 2026. Vol. 61, nr 1, s. 124-132
Nyckelord [en]
diagnostic techniques and procedures, fatty liver, Liver diseases, magnetic resonance imaging, ultrasonography
Nationell ämneskategori
Radiologi och bildbehandling Gastroenterologi och hepatologi
Identifikatorer
URN: urn:nbn:se:umu:diva-248011DOI: 10.1080/00365521.2025.2594790ISI: 001627046300001PubMedID: 41320563Scopus ID: 2-s2.0-105023409583OAI: oai:DiVA.org:umu-248011DiVA, id: diva2:2025484
Forskningsfinansiär
Lions Cancerforskningsfond i Norr, LP 20-2221VetenskapsrådetRegion ÖstergötlandForskningsrådet i Sydöstra Sverige, FORSS, 752871Tillgänglig från: 2026-01-07 Skapad: 2026-01-07 Senast uppdaterad: 2026-01-26Bibliografiskt granskad

Open Access i DiVA

fulltext(2549 kB)45 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 2549 kBChecksumma SHA-512
7cd56437a3c57dfeffeab853e1503877f8feef9e791c3fbeec0c4eec6fc1e0396a14e5f1a7e498628ae8aa0094c07e0d5b301cc7bd43ac42b7f9a380a65de2cb
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Grönlund, ChristerLindam, Anna

Sök vidare i DiVA

Av författaren/redaktören
Grönlund, ChristerLindam, Anna
Av organisationen
Institutionen för diagnostik och interventionInstitutionen för folkhälsa och klinisk medicin
I samma tidskrift
Scandinavian Journal of Gastroenterology
Radiologi och bildbehandlingGastroenterologi och hepatologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 59 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 685 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf