Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Nondipolar content of T wave derived from a myocardial source simulation with increased repolarization inhomogeneity.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0002-1313-0934
2009 (Engelska)Ingår i: Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, ISSN 1542-474X, Vol. 14, nr 2, s. 185-192Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND: Several conditions with repolarization disturbances are associated with increased level of nondipolar components of the T wave. The nondipolar content has been proposed as a measure of repolarization inhomogeneity. This computer simulation study examines the link between increased nondipolar components and increased repolarization inhomogeneity in an established model. METHODS: The simulation was performed with Ecgsim software that uses the equivalent double-layer source model. In the model, the shape of transmembrane potential is derived from biological recordings. Increased repolarization inhomogeneity was simulated globally by increasing the variance in action potential duration and locally by introducing changes mimicking acute myocardial infarction. We synthesized surface ECG recordings with 12, 18, and 300 leads. The T-wave residue was calculated by singular value decomposition. The study examined the effects of the number of ECG leads, changes in definition of end of T wave and random noise added to the signal. RESULTS: Normal myocardial source gave a low level of nondipolar content. Increased nondipolar content was observed in the two types of increased repolarization inhomogeneity. Noise gave a large increase in the nondipolar content. The sensitivity of the result to noise increased when a higher number of principal components were used in the computation. CONCLUSIONS: The nondipolar content of the T wave was associated with repolarization inhomogeneity in the computer model. The measure was very sensitive to noise, especially when principal components of high order were included in the computations. Increased number of ECG leads resulted in an increased signal-to-noise ratio.

Ort, förlag, år, upplaga, sidor
2009. Vol. 14, nr 2, s. 185-192
Nyckelord [en]
principal component analysis, T wave, computer model, simulation, nondipolar components, repolarization inhomogeneity
Identifikatorer
URN: urn:nbn:se:umu:diva-24034DOI: 10.1111/j.1542-474X.2009.00294.xPubMedID: 19419404OAI: oai:DiVA.org:umu-24034DiVA, id: diva2:226005
Tillgänglig från: 2009-06-30 Skapad: 2009-06-30 Senast uppdaterad: 2024-07-02

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Person

Kesek, MilosWiklund, Urban

Sök vidare i DiVA

Av författaren/redaktören
Kesek, MilosWiklund, Urban
Av organisationen
MedicinRadiofysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 285 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf