Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Histological studies of the effects of chronic implantation of ceramic-based microelectrode arrays and microdialysis probes in rat prefrontal cortex.
Umeå universitet, Medicinska fakulteten, Institutionen för integrativ medicinsk biologi (IMB).
Visa övriga samt affilieringar
2009 (Engelska)Ingår i: Brain Research, ISSN 0006-8993, E-ISSN 1872-6240, Vol. 1291, s. 12-20Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Chronic implantation of neurotransmitter measuring devices is essential for awake, behavioral studies occurring over multiple days. Little is known regarding the effects of long term implantation on surrounding brain parenchyma and the resulting alterations in the functional properties of this tissue. We examined the extent of tissue damage produced by chronic implantation of either ceramic microelectrode arrays (MEAs) or microdialysis probes. Histological studies were carried out on fixed tissues using stains for neurons (cresyl violet), astrocytes (GFAP), microglia (Iba1), glutamatergic nerve fibers (VGLUT1), and the blood-brain barrier (SMI-71). Nissl staining showed pronounced tissue body loss with microdialysis implants compared to MEAs. The MEAs produced mild gliosis extending 50-100 microm from the tracks, with a significant change in the affected areas starting at 3 days. By contrast, the microdialysis probes produced gliosis extending 200-300 microm from the track, which was significant at 3 and 7 days. Markers for microglia and glutamatergic fibers supported that the MEAs produce minimal damage with significant changes occurring only at 3 and 7 days that return to control levels by 1 month. SMI-71 staining supported the integrity of the blood-brain barrier out to 1 week for both the microdialysis probes and the MEAs. This data support that the ceramic MEA's small size and biocompatibility are necessary to accurately measure neurotransmitter levels in the intact brain. The minimal invasiveness of the MEAs reduce tissue loss, allowing for long term (>6 month) electrochemical and electrophysiological monitoring of brain activity.

Ort, förlag, år, upplaga, sidor
2009. Vol. 1291, s. 12-20
Nyckelord [en]
Neurotransmitter, Microelectrode, Amperometry, Microglia, Immunohistochemistry, Biosensor
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:umu:diva-32006DOI: 10.1016/j.brainres.2009.06.084PubMedID: 19577548Scopus ID: 2-s2.0-69249202289OAI: oai:DiVA.org:umu-32006DiVA, id: diva2:301373
Tillgänglig från: 2010-03-03 Skapad: 2010-02-26 Senast uppdaterad: 2023-03-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

af Bjerkén, SaraStrömberg, Ingrid

Sök vidare i DiVA

Av författaren/redaktören
af Bjerkén, SaraStrömberg, Ingrid
Av organisationen
Institutionen för integrativ medicinsk biologi (IMB)
I samma tidskrift
Brain Research
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 372 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf