Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Change in intraocular pressure measurement 2 years after myopic laser-assisted subepithelial keratectomy
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.ORCID-id: 0000-0003-0218-4563
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0003-2055-576X
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0002-2031-722X
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Visa övriga samt affilieringar
2012 (Engelska)Ingår i: Journal of cataract and refractive surgery, ISSN 0886-3350, E-ISSN 1873-4502, Vol. 38, nr 9, s. 1637-1642Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: To evaluate intraocular pressure (IOP) measurements 24 months after laser-assisted subepithelial keratectomy (LASEK) with 3 tonometry methods-Goldmann applanation tonometry (DCT), Pascal dynamic contour tonometry (DCT), and applanation resonance tonometry (ART)-and to compare them with measurements taken preoperatively and 3 and 6 months postoperatively. SETTING: Department of Ophthalmology, Umea University, lima Sweden. DESIGN: Prospective randomized single-center. METHODS: One randomized eye per person from myopic healthy individuals who had LASEK was included. Visual acuity, central corneal thickness (CCT), corneal curvature, and IOP were measured at all time points. Six IOP measurements were performed per method, with a 5-minute lapse between methods. RESULTS: The study evaluated 38 eyes. Two years after LASEK, dynamic ART was the only method that did not measure significantly lower IOP than before LASEK (mean -0.2 mm Hg +/- 1.6 [SD]). The greatest difference was with GAT (mean -1.9 +/- 1.7 mm Hg) followed by static ART (mean -1.2 +/- 1.6 mm Hg) and then DCT (mean -0.9 +/- 1.3 mm Hg). All methods measured significantly lower IOP at 3 months and 6 months. CONCLUSIONS: Dynamic ART, which analyses IOP measurement during indentation, showed no significant difference in measured IOP after 24 months. The convex tip of the ART device and the continuous sampling of data during corneal indentation seem to be factors in why dynamic ART was less affected by corneal properties and therefore more suitable for IOP measurement in LASEK-treated eyes, although this must be confirmed in larger trials.

Ort, förlag, år, upplaga, sidor
2012. Vol. 38, nr 9, s. 1637-1642
Nationell ämneskategori
Oftalmologi Kirurgi
Identifikatorer
URN: urn:nbn:se:umu:diva-60651DOI: 10.1016/j.jcrs.2012.04.033ISI: 000308731200019Scopus ID: 2-s2.0-84865243298OAI: oai:DiVA.org:umu-60651DiVA, id: diva2:562900
Konferens
Annual Meeting of the Swedish-Ophthalmological-Society, AUG, 2011, Linkoping, SWEDEN
Tillgänglig från: 2012-10-26 Skapad: 2012-10-22 Senast uppdaterad: 2024-01-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Johannesson, GautiHallberg, PerEklund, AndersLinden, Christina

Sök vidare i DiVA

Av författaren/redaktören
Johannesson, GautiHallberg, PerEklund, AndersLinden, Christina
Av organisationen
OftalmiatrikRadiofysik
I samma tidskrift
Journal of cataract and refractive surgery
OftalmologiKirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 471 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf