Umeå University's logo

umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Subcentimeter Tumor Lesion Delineation for High-Resolution 18F-FDG PET Images: Optimizing Correction for Partial-Volume Effects
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Diagnostic Radiology.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Diagnostic Radiology.ORCID iD: 0000-0001-5227-8117
Show others and affiliations
2013 (English)In: Journal of Nuclear Medicine Technology, ISSN 0091-4916, E-ISSN 1535-5675, Vol. 41, no 2, p. 85-91Article in journal (Refereed) Published
Abstract [en]

In PET, partial-volume effects cause errors in estimation of size and activity for small objects with radiopharmaceutical uptake. Recent methods for image reconstruction, compared with traditional reconstruction techniques, include algorithms for resolution recovery that result in images with higher resolution and enable quantification of size and activity of smaller objects. The purpose of this study was to evaluate a combination of 2 algorithms for volume delineation and partial-volume correction on uptake volumes smaller than 0.7 mL using image reconstruction algorithms with and without resolution recovery.

METHODS: Volumes of interests (VOIs) were delineated using a threshold intensity calculated as a weighted sum of tumor and background intensities. These VOIs were used for calculating correction factors by convolving a tumor mask with the system point-spread function. The methods algorithms were evaluated using a phantom constructed from 5 small different-sized balloons filled with (18)F-FDG in background activity. Six different backgrounds were used. Data were acquired using a PET/CT scanner, and the images were reconstructed using 2 iterative algorithms, one of which used a resolution recovery algorithm.

RESULTS: For the images reconstructed using the resolution recovery algorithm, the method for volume delineation resulted in VOI sizes that were correct within 1 SD for all balloons of a volume of 0.35 mL (equivalent diameter, 8.8 mm) and larger, in all backgrounds. For the images reconstructed without resolution recovery, the VOI sizes were background-dependent and generally less accurate. Correct volume delineations generally led to accurate activity estimates.

CONCLUSION: The algorithms tested on the phantom developed for this study could, for this PET camera and these reconstruction algorithms, be used for accurate volume delineation and activity quantification of lesions 0.35 mL and larger.

Place, publisher, year, edition, pages
Society of Nuclear Medicine and Molecular Imaging , 2013. Vol. 41, no 2, p. 85-91
Keywords [en]
PET, partial-volume effects, partial volume correction, volume delineation, resolution recovery
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:umu:diva-76744DOI: 10.2967/jnmt.112.117234ISI: 000439118600008PubMedID: 23658206Scopus ID: 2-s2.0-84878873137OAI: oai:DiVA.org:umu-76744DiVA, id: diva2:636831
Available from: 2013-07-12 Created: 2013-07-12 Last updated: 2023-03-07Bibliographically approved
In thesis
1. Error reduction strategies for quantitative PET with focus on hybrid PET/MRI
Open this publication in new window or tab >>Error reduction strategies for quantitative PET with focus on hybrid PET/MRI
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Alternative title[sv]
Felreduktionsstrategier för kvantitativ PET med fokus på PET/MR hybridutrustning
Abstract [en]

Positron Emission Tomography (PET) is an important tool for detection, staging and follow-up in a wide range of diseases, including cancer and neurological disorders. As a functional imaging tool, PET can visualize biological processes, where positron emitting radioactive isotopes are connected to molecules with different functions in the body. While PET-images can be visually interpreted, they can also be used for quantitative measurements, where functions such as glucose metabolism, dopamine receptor function, and blood-flow can be quantified. Measurements can be performed in static imaging, or in dynamic imaging where graphical methods can be used for analysis.

PET images benefit from fusion with anatomical images which facilitates the interpretation. The combination of PET with computed tomography (CT) as in PET/CT hybrid equipment is a well-established imaging method. Magnetic Resonance Imaging (MRI) has some advantages over CT such as the high soft tissue contrast, but the combination with PET in a fully integrated system is far more technically challenging. Most of the technical concerns have been solved, and PET/MRI modalities are now commercially available.

Among the remaining challenges, the attenuation correction is still not yet completely solved, where the attenuation maps on the PET/MRI modalities are approximate and bone is not accounted for in all parts of the body. There are also challenges with quantitative PET in general, where for example low spatial resolution and presence of noise can lead to quantitative errors. The purpose of this thesis was to investigate and develop strategies to reduce quantitative errors in PET imaging with special focus on PET/MRI.

In study I, we studied the limits for quantification of size and uptake in small lesions in PET images reconstructed with a resolution modelling algorithm. We constructed a phantom of small balloons and reconstructed images with three different algorithms and measured volume and activity concentration in the images. The measured activity concentration in the lesions was corrected for the low resolution that yields partial-volume effects (PVE). We found that resolution modelling improved quantification of all lesions, and that in combination with correction factors, lesions larger than ~9 mm diameter could be correctly quantified.

Study II is focused on the effect of frame time length on the graphical Logan-analysis for dynamic studies with 11C-raclopride. Logan analysis is reported to be sensitive to noise, and image noise is heavily dependent on the frame time length. Noise can also generate bias when using iterative reconstruction methods. Weivconcluded that with region-based analyses, a bias of approximately 10% in the non-displaceable binding potential was found when using the shortest time frames, and that the bias was mainly caused by the reconstruction algorithm. Long time frames generated stable parameters.

The last two studies focused on the attenuation correction in PET/MRI hybrid equipment. In study III, a method for attenuation correction in PET/MRI was implemented and evaluated. The method is developed for the pelvic region and is based on statistical decomposition of T2-weighted images. We found that the new method improved quantification, especially in regions in vicinity of bone. In study IV, we proposed a concept for patient-specific quality assurance of attenuation maps, based on measurements of the MRI B0-field. The method shows potential to find errors in the attenuation map related to metallic implants, air, and patient contour.

The work in this thesis has contributed to increased knowledge about the effect of resolution and noise for quantification in PET images. It has also introduced a new method for attenuation correction in PET/MRI, and a concept for quality assurance of PET/MRI attenuation maps.

Place, publisher, year, edition, pages
Umeå: Umeå universitet, 2022. p. 58
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 2175
Keywords
Positron emission tomography, PET, PET/MR, PET/MRI, medical imaging, partial-volume effect, attenuation correction
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
radiation physics
Identifiers
urn:nbn:se:umu:diva-194023 (URN)978-91-7855-762-2 (ISBN)978-91-7855-761-5 (ISBN)
Public defence
2022-05-20, Hörsal Betula, målpunkt L, Norrlands universitetssjukhus, Umeå, 09:00 (English)
Opponent
Supervisors
Funder
Swedish Cancer SocietyCancerforskningsfonden i NorrlandVästerbotten County Council
Available from: 2022-04-29 Created: 2022-04-22 Last updated: 2022-04-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Wallstén, ElinAxelsson, JanSundström, TorbjörnRiklund, KatrineLarsson, Anne

Search in DiVA

By author/editor
Wallstén, ElinAxelsson, JanSundström, TorbjörnRiklund, KatrineLarsson, Anne
By organisation
Radiation PhysicsDiagnostic Radiology
In the same journal
Journal of Nuclear Medicine Technology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 673 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf