Variability in prostate and seminal vesicle delineations defined on magnetic resonance images, a multi-observer, -center and -sequence study
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.ORCID-id: 0000-0002-8971-9788
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Onkologi.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Radiation Oncology, E-ISSN 1748-717X, Vol. 8, s. 126-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: The use of magnetic resonance (MR) imaging as a part of preparation for radiotherapy is increasing. For delineation of the prostate several publications have shown decreased delineation variability using MR compared to computed tomography (CT). The purpose of the present work was to investigate the intra- and inter-physician delineation variability for prostate and seminal vesicles, and to investigate the influence of different MR sequence settings used clinically at the five centers participating in the study.

Methods: MR series from five centers, each providing five patients, were used. Two physicians from each center delineated the prostate and the seminal vesicles on each of the 25 image sets. The variability between the delineations was analyzed with respect to overall, intra-and inter-physician variability, and dependence between variability and origin of the MR images, i.e. the MR sequence used to acquire the data.

Results: The intra-physician variability in different directions was between 1.3 - 1.9 mm and 3 - 4 mm for the prostate and seminal vesicles respectively (1 std). The inter-physician variability for different directions were between 0.7 - 1.7 mm and approximately equal for the prostate and seminal vesicles. Large differences in variability were observed for individual patients, and also for individual imaging sequences used at the different centers. There was however no indication of decreased variability with higher field strength.

Conclusion: The overall delineation variability is larger for the seminal vesicles compared to the prostate, due to a larger intra-physician variability. The imaging sequence appears to have a large influence on the variability, even for different variants of the T2-weighted spin-echo based sequences, which were used by all centers in the study.

Ort, förlag, år, upplaga, sidor
BioMed Central, 2013. Vol. 8, s. 126-
Nyckelord [en]
Prostate, Seminal-vesicles, Delineation, Magnetic resonance imaging, Radiotherapy, Variability
Nationell ämneskategori
Radiologi och bildbehandling Cancer och onkologi
Identifikatorer
URN: urn:nbn:se:umu:diva-78454DOI: 10.1186/1748-717X-8-126ISI: 000320268700001Scopus ID: 2-s2.0-84878008150OAI: oai:DiVA.org:umu-78454DiVA, id: diva2:637852
Tillgänglig från: 2013-07-23 Skapad: 2013-07-22 Senast uppdaterad: 2024-07-04Bibliografiskt granskad

Open Access i DiVA

Variability in prostate and seminal vesicle delineations defined on magnetic resonance images, a multi-observer, -center and -sequence study(1838 kB)567 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 1838 kBChecksumma SHA-512
12975994bcd30c9d8493a5feb48c14f88fdd0b1fe63a7d87a87b237ef61458bd1f95b40bbf8434ae450cedc2368fdeb6eb7d50248e25ac7a42f4306c823f0ac0
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Nyholm, TufveJonsson, JoakimSöderström, KarinBergström, PerZackrisson, Björn

Sök vidare i DiVA

Av författaren/redaktören
Nyholm, TufveJonsson, JoakimSöderström, KarinBergström, PerZackrisson, Björn
Av organisationen
RadiofysikOnkologi
I samma tidskrift
Radiation Oncology
Radiologi och bildbehandlingCancer och onkologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 567 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 505 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-6th-edition.csl
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf