gamma-Cyclodextrin Nanoparticle Eye Drops with Dorzolamide: Effect on Intraocular Pressure in Man
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Journal of Ocular Pharmacology and Therapeutics, ISSN 1080-7683, E-ISSN 1557-7732, Vol. 30, nr 1, s. 35-41Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To test a new drug delivery platform with dorzolamide γ-cyclodextrin (γCD) nanoparticle eye drops for intraocular pressure (IOP) control and safety and compare with Trusopt.® Methods: Self-aggregating γCD nanoparticle eye drops containing 3% dorzolamide were given once a day (QD) and compared with Trusopt given three times a day (TID) in a prospective randomized single masked crossover trial over 24 h. Seventeen subjects with IOP over 18 mmHg were recruited. IOP was measured with an Icare Tonometer Pro.® Results: There was no statistically significant difference in the IOP lowering effect of dorzolamide nanoparticle eye drops QD and Trusopt TID. At peak (4 h), the IOP reduction from baseline was 3.8±2.6 mmHg (18%, P<0.05) in the nanoparticle eye drop group and 3.1±3.7 mmHg in the Trusopt group (14%, P<0.05, P=0.97 between groups). At trough (24 h), the IOP reduction was 1.4±2.8 mmHg (6%, P>0.05) in nanoparticle eye drop group and 1.5±2.0 mmHg (7%, P>0.05) in the Trusopt group (P=0.23 between groups). Burning sensation measured on the visual analogue scale (1–100) was less from the nanoparticle eye drops (12±15) than from the Trusopt (37±30), (P=0.0038). Visual acuity and conjunctival hyperemia did not differ between the two groups. Conclusions: Dorzolamide cyclodextrin nanoparticle eye drops QD lower IOP and the effect seems comparable to Trusopt given TID. The nanoparticle eye drops are well tolerated and seem to have a better safety profile than Trusopt.

Ort, förlag, år, upplaga, sidor
2014. Vol. 30, nr 1, s. 35-41
Nationell ämneskategori
Oftalmologi
Identifikatorer
URN: urn:nbn:se:umu:diva-87039DOI: 10.1089/jop.2013.0060ISI: 000331074100006Scopus ID: 2-s2.0-84892910833OAI: oai:DiVA.org:umu-87039DiVA, id: diva2:709034
Tillgänglig från: 2014-03-31 Skapad: 2014-03-18 Senast uppdaterad: 2024-01-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Johannesson, Gauti

Sök vidare i DiVA

Av författaren/redaktören
Johannesson, Gauti
Av organisationen
Oftalmiatrik
I samma tidskrift
Journal of Ocular Pharmacology and Therapeutics
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 346 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf