Umeå universitets logga

umu.sePublikationer
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Compartment Modeling of Dynamic Brain PET: The Effect of Scatter Corrections on Parameter Errors
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
2014 (Engelska)Ingår i: Medical physics (Lancaster), ISSN 0094-2405, E-ISSN 2473-4209Artikel i tidskrift, Meeting abstract (Övrigt vetenskapligt) Published
Abstract [en]

Purpose: To investigate the effects of corrections for random and scattered coincidences on kinetic parameters in brain tumors, by using ten Monte Carlo (MC) simulated dynamic FLT-PET brain scans.

Methods: The GATE MC software was used to simulate ten repetitions of a 1 hour dynamic FLT-PET scan of a voxelized head phantom. The phantom comprised six normal head tissues, plus inserted regions for blood and tumor tissue. Different time-activity-curves (TACs) for all eight tissue types were used in the simulation and were generated in Matlab using a 2-tissue model with preset parameter values (K1,k2,k3,k4,Va,Ki). The PET data was reconstructed into 28 frames by both ordered-subset expectation maximization (OSEM) and 3D filtered back-projection (3DFBP). Five image sets were reconstructed, all with normalization and different additional corrections C (A=attenuation, R=random, S=scatter): Trues (AC), trues+randoms (ARC), trues+scatters (ASC), total counts (ARSC) and total counts (AC). Corrections for randoms and scatters were based on real random and scatter sinograms that were back-projected, blurred and then forward projected and scaled to match the real counts. Weighted non-linear-least-squares fitting of TACs from the blood and tumor regions was used to obtain parameter estimates.

Results: The bias was not significantly different for trues (AC), trues+randoms (ARC), trues+scatters (ASC) and total counts (ARSC) for either 3DFBP or OSEM (p<0.05). Total counts with only AC stood out however, with an up to 160% larger bias. In general, there was no difference in bias found between 3DFBP and OSEM, except in parameter Va and Ki.

Conclusion: According to our results, the methodology of correcting the PET data for randoms and scatters performed well for the dynamic images where frames have much lower counts compared to static images. Generally, no bias was introduced by the corrections and their importance was emphasized since omitting them increased bias extensively.

Ort, förlag, år, upplaga, sidor
American Association of Physicists in Medicine (AAPM) , 2014.
Nationell ämneskategori
Medicinsk bildvetenskap
Forskningsämne
radiofysik
Identifikatorer
URN: urn:nbn:se:umu:diva-98532DOI: 10.1118/1.4888984ISI: 000438439200002OAI: oai:DiVA.org:umu-98532DiVA, id: diva2:783081
Konferens
AAPM Annual Meeting, Austin, TX, USA, July 20-24, 2014
Forskningsfinansiär
Swedish National Infrastructure for Computing (SNIC), 2014/1-260Tillgänglig från: 2015-01-23 Skapad: 2015-01-23 Senast uppdaterad: 2025-02-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Häggström, IdaKarlsson, MikaelLarsson, Anne

Sök vidare i DiVA

Av författaren/redaktören
Häggström, IdaKarlsson, MikaelLarsson, Anne
Av organisationen
Radiofysik
I samma tidskrift
Medical physics (Lancaster)
Medicinsk bildvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 785 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf