Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Age-dependency of ocular parameters - a cross sectional study of young and old healthy subjects
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.ORCID-id: 0000-0003-0218-4563
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF). Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0002-2031-722X
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: Investigative Ophthalmology and Visual Science, ISSN 0146-0404, E-ISSN 1552-5783, Vol. 56, nr 7, artikel-id Meeting Abstract: 116Artikel i tidskrift, Meeting abstract (Övrigt vetenskapligt) Published
Abstract [en]

Purpose: To investigate aging effect on ocular parameters inkluding intraocular pressure (IOP) measured with different tonometry methods in healthy young (HY) and elderly (HE) subjects.

Methods: Fifty eyes of 50 HY subjects (28 females, 22-31 years of age) and 43 eyes of 43 HE subjects (22 females, 64-79 years of age) were included. IOP was measured with four tonometry methods in a standardized order: Ocular Response Analyser (ORA), Dynamic Contour Tonometry (DCT), Applanation Resonance Tonometry (ART) and Goldmann Applanation Tonometry (GAT). Other measurements included axial length (AL), central corneal thickness (CCT), corneal curvature (CC), ocular pulse amplitude (OPA) and aqueous humor (aq).

Results: The mean IOP (HY/HE; mmHg ± standard deviation) was 13.9 ± 2.7/16.4 ± 3.4 with ORA, 15.1 ± 2.1/16.3 ± 3.1 with DCT, 12.3 ± 2.0/13.7 ± 2.8 with GAT and 13.1 ± 2.2/12.1 ± 2.5 with ART. IOP was significantly higher (difference ± standard error) in HE compared to HY measured with ORA (+2.5 mmHg ± 0.6), GAT (+1.4 ± 0.5) and DCT (+1.2 ± 0.6). There was a trend towards lower IOP in HE when measured with ART (-1.0 ± 0.5, p=0.05). There was no difference between HE and HY in CCT, CC, AL or OPA.

Conclusions: Tonometry methods are affected differently by age. IOP was measured higher in elderly people with ORA, DCT and GAT in this Scandinavian population. This effect was not seen in measurements with ART. Other ocular parameters did not differ between the age groups indicating that these measured parameters are not influenced by age in this population.

Ort, förlag, år, upplaga, sidor
Association for Research in Vision and Ophthalmology , 2015. Vol. 56, nr 7, artikel-id Meeting Abstract: 116
Nationell ämneskategori
Oftalmologi
Identifikatorer
URN: urn:nbn:se:umu:diva-111516ISI: 000362882200106OAI: oai:DiVA.org:umu-111516DiVA, id: diva2:875956
Konferens
Annual Meeting of the Association-for-Research-in-Vision-and-Ophthalmology (ARVO), MAY 03-07, 2015, Denver, CO
Tillgänglig från: 2015-12-02 Skapad: 2015-11-13 Senast uppdaterad: 2024-01-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Person

Johannesson, GautiHallberg, PerAmbarki, KhalidEklund, AndersLinden, Christina

Sök vidare i DiVA

Av författaren/redaktören
Johannesson, GautiHallberg, PerAmbarki, KhalidEklund, AndersLinden, Christina
Av organisationen
OftalmiatrikInstitutionen för strålningsvetenskaperCentrum för medicinsk teknik och fysik (CMTF)Radiofysik
I samma tidskrift
Investigative Ophthalmology and Visual Science
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 641 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf