Is p-tert-butylphenol-formaldehyde resin (PTBP-FR) in TRUE Test® (Mekos test) sensitizing the tested patients?
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Dermatologi och venereologi.
2015 (Engelska)Ingår i: Contact Dermatitis, ISSN 0105-1873, E-ISSN 1600-0536, Vol. 73, nr 6, s. 350-357Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

Background: In a population study using TRUE Test®, we noted late reactions to p-tert-butylphenol-formaldehyde resin (PTBP-FR) in 0.5% of subjects tested.

Objectives: In order to explore possible test sensitization, differences in the contents of sensitizers within PTBP-FR in test preparations for TRUE Test® and Finn Chambers® were analysed. Subjects allergic to PTBP-FR and subjects with late reactions to PTBP-FR were retested in order to explore whether these groups reacted to different PTBP-FR sensitizers.

Patients/materials/methods: Four individuals with late reactions and 5 subjects with established allergy to PTBP-FR were retested with defined PTBP-FR sensitizers. PTBP-FR constituents in patches from TRUE Test® were analysed with high-performance liquid chromatography. Previously analysed samples of PTBP-FR constituents served as a reference.

Results: The pattern of reaction to PTBP-FR sensitizers was similar in both groups. Subjects with suspected sensitization had somewhat stronger reactions than controls. The concentrations of monomers, dimers and trimers were generally higher in the TRUE Test® resin than in reference substances.

Conclusions: Retesting did not add information regarding causes of possible sensitization. Analysis showed that the resin used in TRUE Test® has a lower degree of polymerization or condensation, which may enhance its sensitizing properties. A follow-up of late reactions to PTBP-FR in TRUE Test® should be carried out.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2015. Vol. 73, nr 6, s. 350-357
Nyckelord [en]
active sensitization, late reactions, retesting
Nationell ämneskategori
Dermatologi och venereologi Lungmedicin och allergi
Identifikatorer
URN: urn:nbn:se:umu:diva-114628DOI: 10.1111/cod.12401ISI: 000367197500005PubMedID: 25903478Scopus ID: 2-s2.0-84955202628OAI: oai:DiVA.org:umu-114628DiVA, id: diva2:900454
Tillgänglig från: 2016-02-04 Skapad: 2016-01-25 Senast uppdaterad: 2023-03-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Stenberg, Berndt

Sök vidare i DiVA

Av författaren/redaktören
Stenberg, Berndt
Av organisationen
Dermatologi och venereologi
I samma tidskrift
Contact Dermatitis
Dermatologi och venereologiLungmedicin och allergi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 300 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf