Characterization of Beam Shaping Filters and Photon Spectra From HVL Profiles in CT
Visa övriga samt affilieringar
2016 (Engelska)Konferensbidrag, Enbart muntlig presentation (Övrigt vetenskapligt)
Abstract [en]

Purpose: Advanced dosimetry in CT (e.g., the Monte Carlo method) requires an accurate characterization of the shaped filter and radiation quality used during a scan. The purpose of this work was to develop a method where half value layer (HVL) profiles along shaped filters could be made. From the HVL profiles, the beam shaping properties and effective photon spectrum for a particular scan can be inferred.

Methods: A measurement rig was developed to allow determinations of the HVL under a scatter-free narrow-beam geometry and constant focal spot to ionization chamber distance, for different fan angles. For each fan angle, the HVL is obtained by fitting the transmission of radiation through different thicknesses of an Al absorber (type 1100) using an appropriate model. The effective Al thickness of shaped filters and effective photon spectra are estimated using a model of photon emission from a Tungsten anode. This method is used to obtain the effective photon spectra and effective Al thickness of shaped filters for a CT scanner recently introduced to the market.

Results: This study resulted in a set of effective photon spectra (central ray) for each kVp along with effective Al thicknesses of the different shaped filters. The effective photon spectra and effective Al thicknesses of shaped filters were used to obtain numerically approximated HVL profiles and compared to measured HVL profiles (mean absolute percentage error = 0.02). The central axis HVL found in the vendor’s technical documentation were compared to approximated HVL values (mean absolute percentage error = 0.03).

Conclusion: This work has resulted in a unique method of measuring HVL profiles along shaped filters in CT. Further, the effective photon spectra and the effective Al thicknesses of shaped filters that were obtained can be incorporated into Monte Carlo simulations.

Ort, förlag, år, upplaga, sidor
2016.
Nationell ämneskategori
Fysik
Forskningsämne
radiofysik
Identifikatorer
URN: urn:nbn:se:umu:diva-124375OAI: oai:DiVA.org:umu-124375DiVA, id: diva2:951223
Konferens
58th AAPM Annual Meeting and Exhibition 2016, Washington, DC, USA, Jul 31 - Aug 4, 2016
Tillgänglig från: 2016-08-08 Skapad: 2016-08-08 Senast uppdaterad: 2021-08-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Person

Andersson, Jonas

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Jonas
Av organisationen
Radiofysik
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 449 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf